1. In the centre of the connection cover, drill a hole
with a diameter of 10 mm.
2. Place the tension piece and the bolt on the inner
side of the connection cover.
3. Slide the washer over the bolt and tighten the nut
onto the bolt.
4. Tighten the nut by hand. Use a small amount of
grease to make it easier to turn the nut.
5. Using a ring spanner, tighten the nut so that the
connection cover breaks out.
6. Once made a flue gas opening can be closed off
again with the shut-off cover (A). This cover is
not supplied with the appliance. Use the
mounting plate (C) and M6x25 bolt (D) to fit the
cover to the appliance (B); see the following
figure.
The cover (A) can be ordered as an option
using number 01.91659.020.
Subject to change because of technical improvements
7. Fit the connection collar (C) to the flue gas
opening (D) using the two brackets supplied (E)
and the attachment materials (A) and (B); see the
figures below.
8. Use the supplied stove sealant to seal the
connection collar and the cover to the appliance.
09-20020-254
D OVRE
11