Clean filter media
Prerequisite:
• Housing is opened. (→ Opening/closing the housing)
How to proceed:
1. Carefully clean the removed filter media using clean tap water.
2. Also clean the upper filter shell and the filter subshell carefully with clean tap water.
3. Reassemble the unit in the reverse order.
Clean filter pump
Prerequisite:
• Housing is opened. (→ Opening/closing the housing)
How to proceed:
1. Remove the filter pump and the UVC clarifier from the device.
– When doing so, peel off the cable support sleeve on the connection cable from the groove
in the filter subshell.
2. Remove the union nut and pull off the pump.
3. Rotate the pump cover counter-clockwise and remove.
– Pay attention that the seal does not get lost.
4. Pull the running unit out of the pump.
5. Clean all components using clean tap water.
6. Reassemble the unit in the reverse order.
7. Insert the cable support sleeve on the power supply connection cable into the groove on the
filter subshell. (→ Opening/closing the housing)