Important
Those authorised to carry out this oper-
ation must have experience acquired
and certified in the specific sector, must
make the connection to the proper
standards, and must comply with all the
relevant regulations and legislation.
Once the connection has been made,
before the appliance is put into opera-
tion a general check must be made to
ensure there are no gas leaks.
To make the connection, connect the mains line to
the appliance's connection pipe, fitting a shut-off
tap (A), to allow the gas supply to be cut off when
necessary.
Important
The tap (A), not supplied with the ap-
pliance, must be installed in an easily
accessible position and its status (on
or off) must be obvious at a glance.
Important
IT
The connection must be made by author-
ised, skilled personnel, in accordance with
GB
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
DE
pliance is supplied with operating voltage
230V/1N.
FR
ES
English
GAS, CONNECTION
ELECTRICAL CONNECTION
A
A
Important
The gas supply pipe must comply with
the national requirements in force and
must be periodically examined and re-
placed if necessary.
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential safety
breaker close to the appliance.
2 - Pull off the knob (B).
C
H
B
C
D
- 14 -
G
L
F
E