HANDLING AND INSTALLATION
WARNING:Before doing any work,
cut off the general power supply.
The manufacturer has tested the appliance
with its own mains gas, identifi ed by the
sticker applied to the nameplate. If the type
of gas to connected is diff erent from that
used for testing, proceed as follows.
Close the gas supply tap (A).
1)
Change the plate burner nozzle (see page
2)
17).
Replace the top burner nozzles (see pag.
3)
15)
Change the oven burner nozzle (see page
4)
18).
Change the plate burner pilot light nozzle
5)
(see page 18).
Replace the top burner pilot light nozzles
6)
(see page 18).
Change the oven burner pilot light nozzle
7)
(see page 19).
If necessary, replace the oven burner bush-
8)
ing (see page 19).
Adjust the gas control valves of the top
9)
burners (see page 14) and the oven burner
(see page 15) to the minimum setting.
WARNING: Before commissioning the
appliance, the system must be tested to as-
sess the operating conditions of every sin-
gle component and detect any anomalies.
In this stage, it is important to check that all
health and safety requirements are strictly
adhered to.
The following checks should be carried out to
test the system:
Turn on the gas supply tap and check that the
1)
connections are right.
Check that the gas of the network is the same
2)
as that used for commissioning the appliance,
and change it if necessary (see page 13).
3329590_inst_GB_rev.2
CHANGING THE GAS SUPPLY
C
B
10)
11)
tion, check for any gas leaks or faults.
TESTING THE APPLIANCE
3)
4)
5)
6)
7)
If necessary, after testing, train the user by pro-
viding all skills required to safely commission
the appliance, in accordance with applicable
legal requirements.
AL
II2H3B/P: G20/20mbar, G30/30mbar
AL
II2H3+: G20/20mbar, G30-G31/28_30-37mbar
3P
AT
II2H3B/P: G20/20mbar, G30/50mbar
AT
II2H3P: G20/20mbar, G31/50mbar
BE
II2E+3+: G20-G25/20-25mbar, G30-G31/28_30-37mbar
BE
II2E+3B/P: G20-G25/20-25mbar, G30/30mbar
BE
II2E+3P: G20-G25/20-25mbar, G31/37mbar
BE
II2E+3B: G20-G25/20-25mbar, G30/30mbar
BG
II2H3B/P: G20/20mbar, G30/30mbar
BG
II2H3+: G20/20mbar, G30-G31/28_30-37mbar
G20
G31
kW
m3/h
mbar
G25
kW
m3/h
mbar
G30
kW
mbar
Kg/h
G20
G31
kW
m3/h
mbar
G25
kW
m3/h
mbar
G30
kW
mbar
Kg/h
Remove the testing gas sticker from the
nameplate (B) and apply the new one to
identify the gas being used.
Remove the sticker from the appliance and
apply the new one (C) with the category of
the country of installation.
NOTE: After completing the opera-
Check that the plate, top and oven burners are
lighting correctly and their combustion.
Check the gas pressure and fl ow-rate at mini-
mum and maximum settings and adjust if
necessary (see pages 7).
Check that the safety thermocouple is work-
ing correctly.
Check for any gas leaks;
Check that the nameplates specify the correct
gas for the country of use.
ENGLISH
IS
II2H3B/P: G20/20mbar, G30/30mbar
IS
II2H3+: G20/20mbar, G30-G31/28_30-37mb
IT
II2H3+: G20/20mbar, G30-G31/28_30-37mb
IT
II2H3B/P: G20/20mbar, G30/30mbar
IT
II2H3P: G20/20mbar, G31/37mbar
LT
II2H3+: G20/20mbar, G30-G31/28_30-37mb
LT
II2H3B/P: G20/20mbar, G30/30mbar
LT
II2H3P: G20/20mbar, G31/37mbar
LU
II2H3B/P: G20/20mbar, G30/30mbar
LU
II2H3+: G20/20mbar, G30-G31/28_30-37mb
A
kW
mbar
Kg/h
~
~
TYPE
01
0051
kW
mbar
Kg/h
~
~
~
TYPE
13
01
rif.
0051
~
CE n.
rif.