INSTRUCTIONS AND WARNING FOR ADJUSTMENTS
WARNING: In particular, close the gas
supply tap and prevent access to all devices
which might cause unexpected hazards and
damage to people's health and safety if ac-
tivated.
In particular, close the gas supply taps and
prevent access to all devices which might
cause unexpected hazards and damage to
people's health and safety if activated.
ADJUSTING GAS CONTROL VALVE MINIMUM SETTING (PLATE)
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knobs (A).
2)
Undo the screws (C) and remove the control
3)
panel (B).
Remove the injector (D) and replace it with
4)
the one suitable for the type of gas in use
(see table at back of manual).
Fully screw the injector.
5)
After making the setting, seal the screw with
6)
paint.
Replace the control panel (B) and the knobs
7)
(A) on completion of the operation
ADJUSTING THE GAS CONTROL VALVE TO THE MINIMUM SETTING
To carry out this operation, proceed as follows.
Close the gas supply tap.
1)
Pull off the knobs (A).
2)
Undo the screws (B) and remove the control
3)
panel (C).
Remove the injector (D) and replace it with
4)
the one suitable for the type of gas in use
(see table at the end of the manual).
Fully screw the injector
5)
After making the adjustment, seal the screw
6)
with paint.
After completing the operation, fi t the con-
7)
trol panel (C) and the knob (A) back in place.
14
ADJUSTMENTS
quired if the type of gas to be connected is
diff erent from that used for testing, after
changing the gas supply (see page 13).
ried out by authorised, qualifi ed staff , in ac-
cordance with the relevant legal require-
ments.
NOTE: These adjustments are only re-
WARNING: Adjustments must be car-