Troubleshooting - Lincoln Quicklub V10 Instrucciones De Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

User Manual
Operating Instructions
NOTE
The pump operation can be stated from the outside by:
- the rotating stirring paddle (e.g. by triggering an additional lubrication cycle)
- the LEDs of the control p.c.b. (see chapter "Fault indication")
- the signal lamp of the illuminated pushbutton (option)
6001a02
Fault: The pump motor does not run
Cause:
Power supply to the pump interrupted
Power supply to the control p.c.b.
interrupted
Control p.c.b. defective
Electric motor defective
Fault: Right-hand LED 3 (see fig. 9) flashes
Cause:
One of the two rotary switches 2, 4 is
on „0".
Signal: 4 flashes
Short circuit at pushbutton of the
control p.c.b. or, if present, at the
external illuminated pushbutton or at
their connecting parts.
Signal: 3 flashes
Page 10 of 22
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259

Troubleshooting

Remedy
Check the power supply and fuses.
If necessary rectify the fault and/or replace the fuses.
Check the line leading from the fuses to the pump plug.
Check the line leading from the pump plug and the control
p.c.b.
If the power supply is connected, the left-side LED is lit (see
4273a00
fig. "PCB 8").
Check the function of the p.c.b. (see fig. "PCB 8"). If necessary replace the p.c.b.
Check the power supply to the motor. If necessary, replace the motor.
Remedy:
Set rotary switch to a number or a letter.
Check whether the short circuit is at the PCB or, if present, at the illuminated
pushbutton. If necessary, exchange the PCB or the illuminated pushbutton.
2.6EN-28006-E11
by service personnel
by service personnel