OPERATION MODES
Semiautomatic mode (DIP4 OFF and DIP10 OFF)
Opening: this begins by operating the corresponding
control (magnetic key, key selector, remote control,
etc).
• Step-by-step opening (DIP3 ON): If, during the
opening process, the corresponding control is ope-
rated, the gate comes to a halt. The gate closes
when operated again.
• Community opening (DIP3 OFF): During opening,
the control panel does not obey the control orders.
Automatic mode (DIP4 ON)
Opening: this begins by operating the corresponding
control (magnetic key, key selector, remote control,
etc).
• Step-by-step opening (DIP3 ON): If, during the
opening process, the corresponding control is
operated, the gate comes to a halt. The gate closes
when operated again.
• Community opening (DIP3 OFF): During opening,
the control panel does not obey the control orders.
Dead man mode (DIP4 OFF and DIP10 ON, TOP9 only)
In this case the gate cannot be operated using the remote control.
Opening: It is necessary to keep the total opening
button pressed down (ST1). The gate will stop if the
button is released.
DESCRIPTION OF THE PRODUCT
Standby: The gate remains open indefinitely until the
button or remote control is operated.
Close: The closing process starts up by operating the
corresponding control.
If, during the closing process, the button or the re-
mote control is operated, the gate inverts the opera-
tion direction and it opens completely.
S t a n d b y : T h e g a t e r e m a i n s o p e n d u r i n g t h e
programmed time.
• DIP6 OFF: If, during the waiting time, the control or
the photocells are enabled, the waiting time starts
again.
• DIP6 ON (automatic mode optional): If, during
the waiting time, the control is operated, the gate
begins to close after 3 seconds of waiting. If the
photocells are activated, the waiting time restarts.
• DIP11 ON (exclusive mode, TOP9 only):
– DIP10=OFF: If, during the wait, the exterior
photocell detects that a person or object has
passed, the gate begins to close.
– DIP10=ON: If, during the wait, the exterior and
interior photocells detect that a person or object
has passed, the gate begins to close.
Close: At the end of the waiting time (or when
operating the control or key if DIP 6 ON, or when a
person or object passes if DIP 11 ON), the closing
operation starts.
If, during the closing, the button or the remote
control is operated, the gate inverts the operation
direction and it opens completely.
Standby: The gate remains open indefinitely until the
button is pushed.
Close: It is necessary to keep the pedestrian closing
button pressed down (ST2). The closing operation is
carried out at a single speed (there is no slowdown
towards the end).