DIP10: dead man mode (only with DIP4=OFF and
DIP11=OFF) (TOP9 only)
DIP10=ON: dead man function enabled.
Opening and halting: briefly pressing ST1.
Close: pressing down ST2. Closing takes place at a
single speed.
DIP10=OFF: dead man function disabled.
DIP11: exclusive mode (only with DIP4=ON) (TOP9
only)
DIP11=ON and DIP10=ON: exclusive mode
with exterior and interior photocells
DIP11=ON and DIP10=OFF: exclusive mode
with exterior photocell
DIP11=OFF: exclusive mode disabled
2
CONNECTION TO THE POWER SUPPLY AND CHECKING OF ROTATION DIRECTION
1 Connect the main circuit breaker of the control
panel.
The correct operation of the operator and of the
complete system will only be achieved following the
programming. However, prior to programming it is
necessary to check that all the elements work,
carrying out the checks listed below.
3
RECORDING OF THE RADIO CODE (ONLY FOR RSD-001)
When using the ERREKA RSD-001 plug-in card (fixed Reson code 433Mhz) as the receiver for the remote control,
the radio code can be recorded in the control panel itself, as explained below. In the other boxes, follow the
instructions of the receiver card used.
Recording of the total opening code
Recording of the pedestrian opening code
PROGRAMMING AND STARTING UP
DIP12: operator
with
(VULCAN VUS)
DIP12=OFF:
operator
connected.
DIP12=ON: VULCAN VUS operator safety device
connected instead of FCA. A collision during closing
causes a stop and inversion. A collision during
opening causes a stop.
2 Check the rotation direction of the motor using
mini-buttons PUL1 and PUL2.
If the direction of any motor is not correct,
interchange the connection cables (Rotation1 and
Rotation2) in the corresponding connector for the
motor.
Before carrying out any gate movement,
ensure there is no person or object in the radius
of action of the gate and the operation
mechanisms.
1 Connect the power supply of the panel (SW1 in
"ON").
2 Close the leaves by pressing ST1.
3 Place DIP1 and DIP 4 in "ON"; DIP2, DIP3, DIP5 and
DIP6 in "OFF" (DL3 lights up, statically).
4 Select the required code in the control.
5 Press the channel to be used for total opening until
DL2 flashes on and off.
6 Place DIP1 and DIP4 in "OFF" (DL2 and DL3 go off).
1 Connect the power supply of the panel (SW1 in
"ON").
2 Close the leaves by pressing ST1.
3 Place DIP1 and DIP 6 in "ON"; DIP2, DIP3, DIP4 and
DIP5 in "OFF" (DL3 lights up, statically).
4 Select the required code in the control.
5 Press the channel to be used for pedestrian opening
until DL2 flashes on and off.
6 Place DIP1 and DIP6 in "OFF" (DL2 and DL3 go off).