OPERATION
ADDING GASOLINE
See Figures 9 - 10.
DANGER
remove the fuel cap or refuel the generator while the
engine is running. Do not smoke or create sparks while
fueling. Always turn the engine off and allow the gen-
erator to cool for at least five minutes before refueling.
DANGER
not overfill fuel tank. Fill only to the red maximum fill
ring on the fuel screen. Overfilling may cause fuel to
spill onto engine causing a fire or explosion hazard.
WARNING
gasoline tank, or any other fuel item that is broken, cut,
torn or damaged.
NOTICE
Only fill the tank from an approved gas-
oline container. Make sure the gasoline container is
internally clean and in good condition to prevent fuel
system contamination.
l Turn the generator off and allow the engine to cool for at
least five minutes.
l Place the generator on a level surface in a well-ventilated
area. DO NOT fuel indoors.
l Clean area around fuel cap and remove the cap slowly.
l Slowly add the recommended fuel. Do not overfill.
NOTE: The gasoline level should NOT be higher than the
red maximum fill ring on the fuel screen.
l Install the fuel cap. Tighten securely.
l Clean up any spilled fuel.
l Move at least 30 ft. away from refueling area before re-
starting the engine.
NOTICE
Fuel can damage paint and plastic. Use
caution when filling the fuel tank. Damage caused by
spilled fuel is not covered under warranty.
NOTICE
Clean the fuel screen filter of debris be-
fore and after each fueling. Remove the fuel screen
filter by slightly compressing it while removing it from
the fuel tank.
16 | English
Fire and explosion hazard. Never
Fire and explosion hazard. Do
Never use a gasoline container,
FIG. 9
A - Vented Fuel Cap
FIG. 10
A - Vented Fuel Cap
B - Max Fill Line
C - Screen Filter
HIGH ALTITUDE OPERATION
Engine power is reduced the higher you operate above sea
level. Output will be reduced approximately 3.5% for every
1,000 feet of increased altitude from sea level.
High altitude adjustment is required for operation at altitudes
over 5,000 ft. (1524 m). Operation without this adjustment
will cause decreased performance, increased fuel consump-
tion, and increased emissions.
NOTICE
DO NOT operate the generator at
altitudes below 2,000 ft. (762 m) with the high altitude
kit installed. Engine damage may occur.
High Altitude
Carburetor Kit
A
A
B
C
Part# 518518-01