Descargar Imprimir esta página

WIKA DPGS40TA Manual De Instrucciones página 25

Manómetro diferencial con microswitch, con prueba de componentes
Ocultar thumbs Ver también para DPGS40TA:

Publicidad

Idiomas disponibles

Idiomas disponibles

6. Commissioning, operation
Measuring assemblies
The preferred measuring assemblies for various possible applications are
specified in DIN 19216.
The following schematic diagram shows a recommended assembly for liquid
media. As throttling devices, differential pressure transducers should be provided
in accordance with DIN 1952 (issue 07.82), now replaced by EN 5167/1.
Ensure that the differential pressure lines are made of metal, that the bore is not
less than 4 mm and the effective length between the valve manifold and the differ-
ential pressure measuring instrument is at least 500 mm.
The length and the bore of the differential
pressure lines are to be dimensioned
in such a way that, on cold lines, the
response time of the effective pressure
measuring instrument is not more than 5
seconds.
Ensure that the connections of the
differential pressure lines are welded,
brazed or screwed using metal sealing
elements.
The only way to actuate the shut-off
devices in differential pressure lines is
with tools.
6.2 Electrical connection
The electrical connection must only be made by qualified skilled personnel.
Connection details and switching functions are given on the product label.
Connection terminals are appropriately marked.
Rate mains connection cables for the maximum current consumption of the
appliance and comply with the specifications of IEC 227 or IEC 245.
Include instruments in the equipotential bonding of the plant.
For performance data, see chapter 3 "Specifications"
WIKA operating instructions DPGS40TA with component testing
Differential pressure
transducer
(throttling device in the
process line)
Differential pressure
line
Shut-off valves
(valve manifold)
Differential pressure
measuring instrument
DPGS40TA
EN
25

Publicidad

loading