Descargar Imprimir esta página

GreenWorks MZ548 Manual Del Operador página 46

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
16.5 MIDDLE BLADE MOTOR CONTROLLER ERROR CODES
Error Co-
Error Contents
des
MM 2
Blade motor stalled
MM 6
Controller phase loss
MM 7
MOSFET error
MM 8
Controller undervolt-
age
MM 9
Controller overvoltage The voltage is too high. Restart the power supply.
MM 13
Controller overtemper-
ature
MM 14
Software overcurrent
MM 15
Hardware overcurrent
MM 19
Operating sequence
error
MM 25
CAN timeout error -
left drive
MM 26
CAN timeout error -
right drive
MM 27
CAN timeout error -
left blade
MM 28
CAN timeout error -
central blade
MM 29
CAN timeout error -
right blade
MM 31
Failed to verify blade
signal
MM 32
Software authentica-
tion error
MM 42
Software Version veri-
fication error
English
Suggestions
Check the mowing load and return the blade start switch to its initial position.
Check that motor cables of the drive controller are connected properly, and
then restart the power supply.
If you encounter this issue, contact your distributor for a solution.
The voltage is too low. Charge the battery pack before use.
The controller temperature is too high. Wait for the controller to cool down,
and then restart the power supply
The load is too high. Restart the power supply.
The load is too high. Restart the power supply.
Place the left and right handles in the park position, and the blade start switch
in the OFF position. Sit in the seat and try again.
Communication failure with the left drive controller. Restart the power supply.
Communication failure with the right drive controller. Restart the power supply.
Communication failure with the left blade controller. Restart the power supply.
Communication failure with the central blade controller. Restart the power
supply.
Communication failure with the right blade controller. Restart the power sup-
ply.
Check that the blade start switch is connected properly, and then return the
switch to its initial position.
Restart the power supply.
Restart the power supply.
46

Publicidad

loading

Este manual también es adecuado para:

Mz608