Descargar Imprimir esta página

Fronius STRING CONTROL 125/25 Manual De Instrucciones página 14

Supervisión del equipo
Ocultar thumbs Ver también para STRING CONTROL 125/25:

Publicidad

Idiomas disponibles

Idiomas disponibles

Ordering fuses
Fuses with nominal values of 5 A, 10 A and 20 A can be ordered from Fronius by quoting
the following item numbers:
-
-
-
Setting the address
Safety
Jumper and
adjusting dials
Fig. 4 Jumpers and adjusting dials
Setting the Solar
Net address
Fig. 5 Solar Net address
Littelfuse KLKD-5 (41,0007,0205)
Littelfuse KLKD-10 (41,0007,0207)
Littelfuse KLKD-20 (41,0007,0200)
WARNING! The solar modules operate at high voltage. Before performing any
work on the Fronius String Control 125/25, de-energise the solar module
(1) (2)
(3)
Fronius String
Control 125/25
No.:
1
0
37
0
123
1
The Solar Net allows up to 200 Fronius
String Controls 125/25 to be operated
simultaneously. The Fronius String Cont-
rols 125/25 are allocated addresses to
distinguish them from one another. To set
the address (0 to 199), use
-
-
-
The procedure can be seen in the examp-
les illustrated.
0
1
3
7
2
3
6
jumper (1)
adjusting dial (2)
adjusting dial (3)

Publicidad

loading