TROUBLESHOOTING
PULSATING FLOW, PUMP CYCLES ON AND OFF
• Restricted pump delivery
• Check discharge lines, fittings and valves for undersizing or
clogging
MOTOR OPERATES, BUT PUMP FAILS TO PRIME
• Restricted intake or discharge line
• Air leak in intake line
• Punctured pump diaphragm
• Debris under flapper valves
• Crack in pump housing
MOTOR FAILS TO TURN ON
• Loose wiring connection
• Pump circuit has no power
• Blown fuse/Thermal Protector tripped
• Pressure switch failure
• Defective motor
OPTIONAL PORT KITS
30649-1004
1/2-14 Male
Straight Thread
Port Kits contain two ports with O-rings.
30653-1004
30654-1004
3/4" Straight
1/2" Straight
Hose Barb
Hose Barb
THE PRODUCTS DESCRIBED HEREIN ARE SUBJECT TO THE JABSCO
ONE YEAR LIMITED WARRANTY, WHICH IS AVAILABLE FOR YOUR
INSPECTION UPON REQUEST.
PUMP FAILS TO TURN OFF AFTER ALL VALVES ARE CLOSED
• Empty water tank
• Punctured pump diaphragm
• Discharge line leak
• Defective pressure switch
• Insufficient voltage to pump
• Debris under flapper valves
LOW FLOW AND PRESSURE
• Air leak at pump intake
• Accumulation of debris inside pump and plumbing
• Worn pump bearing (excessive noise)
• Punctured pump diaphragm
• Defective motor
30651-1004
90° - 3/4"
Hose Barb
6
30651-1004
90° - 1/2"
Hose Barb

Publicidad

loading