Descargar Imprimir esta página

RIB PRINCE 24V Wi-Fi Manual De Instrucciones página 32

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

G
B
A -
CONTROL PANEL FEATURES
J2
J9
J10
J8
J7
S3
B
- SETTINGS
DIP 1
(ON) - MOTOR ROTATION DIRECTION CONTROL (POINT C)
DIP 2
(ON) - TIMER (POINT D)
DIP 3
(ON) - ACTIVATES DOOR RELEASE DURING PHASES OF SLOWDOWN AND TOTAL
OPENING AND CLOSING (AS PER THE IMPACT TESTS OF EN12453)
DIP 1-2 MEMORIZATION/CANCELLATION OF RADIO CONTROL CODES FOR TOTAL OPENING
(ONLY MODEL CRX) (POINT E)
DIP 1-3 MEMORIZATION/CANCELLATION OF RADIO CONTROL CODES FOR PEDESTRIAN
OPENING (ONLY MODEL CRX) (POINT F)
DIP 2-1 MICRO-SWITCH CONTROLLER FOR PEDESTRIAN OPENING TIMER
DIP 4
Photocells always active (OFF) - Photocells active only during closing (ON)
DIP 5
Pre-blinking (ON) - Normal blinking (OFF)
DIP 6
Single pulse command (K BUTT) and step-by-step radio receiver (OFF) - automatic (ON)
DIP 7
Power sensor operation (ON-activated) time operation (OFF-activated).
DIP 8
Electric lock activation (ON-activated)
DIP 9
Electric lock pulse release (ON-activated)
DIP 10 Electric lock pulse engagement (ON-activated)
DIP 11 Easy release activation (ON-activated)
DIP 12 Sensor TEST activation (ON-activated).
DIP 13 Selection of 1 or 2 motor operation (default OFF 2 motors)
DIP 14 OFF
DIP 15 OFF
DIP 16 IMMEDIATE CLOSING AFTER PASSING IN FRONT OF PHOTOCELLS
ON
ACTIVATED
OFF
DEACTIVATED
JP1 => Check that the jumper is inserted!
JP2 => Check that the jumper is inserted!
JP3 => Check that the jumper is inserted!
PROG =>
S3 Programming button
ADJUSTMENTS
ATTENTION: PUT DIP 3 IN THE ON MODE ONLY AFTER HAVING CARRIED OUT ALL THE
J1
F1
J3
TRANSFORMER
J4
FUSE 1
J5
J6
TR3
TR1
TR2
J1
N F
J2
COM.
CLOSE
OPEN
STOP
AERIAL
J3
SIGNAL
A+TEST
EDGE N.C.
COM.
PHOTO N.C.
K BUTT.
PED. BUTT.
A+
A -
LOCK
J4
SECONDARY
TRANSFORMER
J5
MOTOR 1
J6
MOTOR 2
J7
SW T2 24V
J8
SW RADIO
J9
RADIO
J10
BATTERY CHARGER
TR1
TRIMMER RUN
TR2
TRIMMER LOW SPEED
TR3
TRIMMER TCA
S3
PROG
FUSE 1
T 8 A
F1
T 2 A
PROGRAMMING PROCEDURES.
NOTE: WITH DIP 3 (ON) BRIEF GATE REVERSAL AFTER IMPACT IS ACTIVATED.
THIS BRIEF GATE REVERSAL PERMITS STATIC FORCE TO BE REDUCED TO ZERO WITHIN 5
SECONDS AS PER STANDARD EN12453 POINT A.2.2 (ACCEPTABLE STATIC FORCE), THEREBY
COMPLYING WITH THE IMPACT TESTS ALSO OUTLINED BY EN12453).
IF COMPLIANCE WITH THE AFOREMENTIONED STANDARD IS UNNECESSARY, SIMPLY
POSITION DIP 3 TO OFF. IN THIS CASE THE GATES STOP WITHOUT REVERSING.
RUN TRIMMER (TR1) high-speed electronic regulator
This trimmer permits motor speed adjustment (the default setting is maximum speed). Adjustment of
the automation is useful for compliance with European impact standards.
LOW-SPEED TRIMMER (TR2) Electronic slow speed approach control
The slow speed control is performed by adjusting the LOW- SPEED TRIMMER which changes the
voltage output across the motor(s) (turning it clockwise increases the speed). Adjustment is performed
to determine the correct speed at the end of opening and closing according to the gate or when there
is friction that might cause the system to function poorly.
AUTOMATIC CLOSING TRIMMER - TCA (TR3) TOTAL OR PEDESTRIAN default NOT ACTIVATED
and LED DL6 OFF (TRIMMER FULLY ROTATED COUNTERCLOCKWISE)
This trimmer makes it possible to adjust the time for total or pedestrian automatic closing. Only with
gate completely (total) or partially (pedestrian) open and LED DL6 on (trimmer rotated clockwise).
The pause time can be adjusted from a minimum of two seconds up to a maximum of two minutes.
LED SIGNALS
DL1 program activated (red)
DL2 gate opening M2 (green)
DL3 gate closing M2 (red)
DL4 gate opening M1 (green)
DL5 gate closing M1 (red)
DL6 automatic closing indicator (red)
32
32
Power supply 230 Vac 50/60 Hz - external to the
control panel - (120V/60Hz upon request)
Common contact
Closing impulse contact (NA)
Opening impulse contact (NA)
STOP impulse contact (NC)
Radio Antenna
Gate open state and battery state output indicator
(24Vdc 3W max)
+ 24Vdc safety strip self-test power supply
Safety strip contact (NC)
Common contact
Photocells contact (NC)
Single pulse contact (NO)
Pedestrian opening contact (NA)
+ 24Vdc accessories power supply
- 24Vdc accessories power supply
Electric lock connection (MAX 15W 12V)
- 24Vdc blinker (code ACG7061) power supply. Pay
attention to the polarity.
Connection to secondary coil of transformer 18 Vac
MOTOR 1 CONNECTION (without polarity)
MOTOR 2 CONNECTION (without polarity)
Connector dedicated to the factory programming.
DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT WORK!
Connector dedicated to the factory programming
(only CRX control board)
DO NOT REMOVE ANY JUMPER!
OTHERWISE THE OPERATOR WILL NOT WORK!
Built-in radio module (model CRX), or connector for
radio receiver RIB, 24 Vdc supply
Connector for charge card of 24Vdc battery (code
ACG4648)
Trimmer for high speed adjustment operations
Trimmer for low speed adjustment operations
Trimmer for automatic closing time adjustment
(DISABLED DEFAULT AND DL6 LED OFF)
Programming button
Motor protection fuse
Transformer protection fuse

Publicidad

loading

Este manual también es adecuado para:

Prince 24vAd00732Ad00734