The device is not suitable for:
● Operation in potentially explosive at-
mospheres.
Description of the unit
See graphics page for illustrations
Illustration A
Collection container
1
PE dust bag
2
PE dust bag fastener
3
Push handle
4
Suction hose connection
5
Equipotential bonding cable
6
Bag filter
7
Mains cable
8
Gauge
9
Power switch
10
Equipotential bonding cable
11
Suction head lock
12
Equipotential bonding cable
13
Pressure equalization tube
14
Accessory holder
15
Lower collection container lever
16
Steering rollers with parking brake
17
Initial startup
See graphics pages for illustration
1. Bring the device into the working posi-
tion.
2. If necessary, secure the device using the
parking brake.
3. Ensure that the suction head is fitted
correctly.
4. Insert the suction hose into the suction
hose connection.
Illustration B
5. Plug the desired accessory onto the suc-
tion hose.
Operation
See graphics pages for illustration
1. Plug the mains plug into the socket.
2. Switch on the device using the trigger.
Illustration C
The switch has multiple level settings:
0 The device is off.
1 Motor 1 is switched on.
2 Motors 1 and 2 are switched on.
3. Start the vacuuming process.
Suction process
See graphics page for illustrations
Illustration D
Holder
1
Suction hose
2
Accessory holder
3
Nozzle
4
1. Switch the device on.
2. Remove the suction hose from the hold-
er.
3. Take the desired nozzle out of the ac-
cessory holder and attach it to the suc-
tion hose.
4. Vacuum up the desired material.
5. Take the nozzle off the suction hose and
place it into the accessory holder.
6. Place the suction hose on the holder.
7. Switch off the device.
Cleaning the dust filter
See graphics page for illustration
Note
Clean the filter regularly to avoid declining
suction power.
Illustration E
1. Move the filter cleaning handle back and
forth several times to clean the filter.
Reading the minimum volumetric
A gauge is mounted on the front of the de-
vice that shows the vacuum intensity.
(see chapter Description of the unit)
The table shows the maximum vacuum in-
tensity value. This value depends on the
unit performance and the suction hose
used.
ATTENTION
Suction loss
If the specified value is exceeded, the air
speed in the suction hose drops below
20 m/s.
Clean the bag filter when the value is
reached, or sooner.
If cleaning does not significantly lower the
value, change out the bag filter.