GARANT Electronic torque/rotational angle wrench HCT
de
Status
Up
Up
func-
tion
button
en
In meas-
Show
-
bg
urement
last five
mode
meas-
"Indicat-
ure-
ing"
ments
da
In meas-
Show
-
fi
ure-
last five
ment
meas-
mode
ure-
"Trig-
ments
fr
gering"
Within a
Step
Menu
it
menu
back
item up
hr
lt
Config-
Step
Increase
uration
back
value
of a set-
ting
nl
3.3.
DISPLAY
no
1 2 3
18
Peak: 110,1°
pl
17
16
pt
15
not calibrated
ro
14
1
Battery capacity
2
Bluetooth (if Bluetooth activated) 11
sv
3
Fault symbol/message symbol (if
there is a fault)
sk
4
Memory almost at maximum ca-
pacity
5
Date
sl
es
6
Time
7
Display the last five measurement
values
cs
8
Scale display
9
Current torque angle
hu
16
Down
OK
Left
Right
Down
func-
tion
button
seconds
: switch
on
-
Switch
-
-
Switch
to
to menu
menu.
Longer
than
two
seconds:
switch
off
-
Switch
-
-
Switch
to
to menu
menu.
Longer
than
two
seconds
: switch
off
Menu
Call up
-
-
Con-
item
menu
firm/de-
down
item.
lete
Longer
than
two
seconds:
switch
off
Reduce
Con-
Position
Position
Confirm -
value
firm.
to the
to the
Longer
left
right
than
two
seconds
: switch
off
4
5
6
7
20.07.2020 16:32
72,3
110,1°
123,0°
30,0
Nm
ARB1
1/9
12
13
10
Angle Target value
Menu
12
If tightening procedure executed
according to workflow: current
screw case / total number of
screw cases
13
Name of active workflow or screw
case
14
"Not calibrated" on a grey back-
ground:
Measurement within the calib-
rated range.
"Not calibrated" lights up:
Measurement within the non-cal-
ibrated range.
15
Torque Target value
16
Current torque
17
Configured direction of tighten-
ing
18
Peak value of the current meas-
urement
3.4.
COMPATIBILITY WITH BLUETOOTH DEVICES
Send
button
This device uses Bluetooth® technology (Bluetooth Low Energy) and meets the re-
quirements of Bluetooth 5.0. When connecting to a computer, smartphone or tablet
via HID, measurements can be sent to any program. Minimum requirement:
Bluetooth 4.2.
Connection options
Reset
Computer
value.
Smartphone
If con-
nected
Tablet
to a
*
All versions supported by Microsoft.
com-
puter:
4.
Transport
transfer
Transport in the original packaging at temperatures between -20°C and +70°C and at
value
a humidity below 90%, non-condensing. Prevent from falling.
If con-
5.
Conditions of the working environment
nected
to a
Temperature
com-
Relative atmospheric humidity
puter:
transfer
Height above mean sea level (MSL)
value
Pollution degree
6.
Initial commissioning
-
A
CAUTION
Exploding rechargeable batteries
Risk of injury to hands and body.
»
Use only the rechargeable battery supplied.
»
In the event of damage, deformation or heat build-up, stop using the re-
chargeable battery.
»
Only charge rechargeable batteries with the corresponding charger.
1. Turn rotary catch anti-clockwise with slot-head screwdriver and remove it.
2. Remove contact fuse.
3. Insert rotary catch and turn clockwise with slot-head screwdriver.
7.
Switching on torque wrench
B
i
Torque wrench is tared automatically each time it is switched on.
1. Place the torque wrench on a flat surface and keep it still.
2. Press the OK button and keep it depressed for around two seconds in order to
switch on the torque wrench.
»
"Tare - Do not move" is displayed.
8
CAUTION! Incorrect taring. Do not apply any loads to or move the torque
wrench during the taring process.
9
3. If the torque wrench switches to measurement mode, the taring process is com-
plete.
10
»
The measurement mode last used is displayed.
11
8.
Menu navigation
8.1.
MEASUREMENT MODES
8.1.1.
Torque
20.07.2020
16:32
Peak: ---
0
Nm
1. Press the down function button or OK, enter the password if necessary and con-
firm with OK.
2. Select "Mode" and confirm with OK or the down function button.
3. Select "Torque" and confirm with OK or the down function button.
4. Select "Indicating" mode and confirm with OK or the down function button to
measure the torque without configuring further settings.
Select "Triggering" mode in order to configure further settings.
5. In the mode "Triggering", configure the following device settings and confirm
with OK or Lower function button:
UNITS
TARGET VALUE
MIN TOLERANCE
MAX TOLERANCE
DIRECTION OF ROTATION
Bluetooth (to connect to
HID
the app)
Windows 10 or later
Windows
Android, iOS
Android, iOS
Android, iOS
Android, iOS
-10 °C to +40 °C
90 %, non-condensing
0 m to 2000 m
3
20.07.2020
16:32
MODE
Measurement method
History
Torque
Connection
Data transfer
Workflow
Define desired unit for torque.
Define value of the target torque.
Define the lower tolerance limit for torque.
Define the upper tolerance limit for torque.
Define direction of tightening.
*
MODE
Indicating
MODE
Triggering