ANGULAR MONITORING
Activate or deactivate subsequent angle of rotation
measurement.
1. For subsequent angle of rotation measurement, configure the following addi-
tional settings and confirm with OK or Lower function button:
SNUG TORQUE
Define value of the snug torque.
MIN ANGLE
Define the lower tolerance limit for target angle.
MAX ANGLE
Define the upper tolerance limit for target angle.
1. Then save the screw case.
8.1.2.
Angle of rotation
20.07.2020
16:32
Peak: ---
Measurement method
History
0
Connection
Nm
Data transfer
Workflow
1. Press the down function button or OK, enter the password if necessary and con-
firm with OK.
2. Select "Mode" and confirm with OK or the down function button.
3. Select "Angle" and confirm with OK or the down function button.
4. Make the following settings and confirm with OK or the down function button:
UNITS
Define desired unit for torque.
SNUG TORQUE
Define value of the snug torque.
TARGET ANGLE
Define value of the target angle.
MIN TOLERANCE
Define the lower tolerance limit for angle of rotation.
MAX TOLERANCE
Define the upper tolerance limit for angle of rotation.
DIRECTION OF ROTATION
Define direction of tightening.
TORQUE MONITORING
Activate or deactivate subsequent torque measure-
ment.
1. For subsequent torque measurement, configure the following additional settings
and confirm with OK or Lower function button:
MIN TARGET VALUE
Define the lower tolerance limit for torque.
MAX TARGET VALUE
Define the upper tolerance limit for torque.
1. Then save the screw case.
8.2.
HISTORY
20.07.2020
16:32
Peak: ---
Measurement method
History
0
Connection
Nm
Data transfer
Workflow
i
A maximum of 1000 entries can be saved. After this, the oldest entries are overwrit-
ten.
1. Press the down function button or OK, enter the password if necessary and con-
firm with OK.
2. Select "History" and confirm with OK or the down function button.
3. Select entry.
In order to display details, press OK.
In order to delete all entries, press and hold the down function button for three
seconds and confirm with OK or the down function button.
8.3.
SCREW CASE
8.3.1.
Creating screw case
20.07.2020
16:32
20.07.2020
16:32
Peak: ---
Data transfer
Workflow
0
Screw cases
Nm
Settings
Info
i
A maximum of 100 screw cases can be saved.
1. Press the down function button or OK, enter the password if necessary and con-
firm with OK.
2. Select "Screw cases" and confirm with OK or the down function button.
3. Select "New screw case" and confirm with OK.
4. Assign a name with a maximum of four characters using the up, down, left and
right buttons.
5. Confirm with OK or the down function button.
6. Select with the left and right buttons whether the screw case is to be password-
protected and confirm with OK or the down function button.
i
In the case of active Screw case PWD: Password must be entered in the case of
an incorrectly executed tightening procedure.
7. Configure settings according to Measurement modes [} Page 16].
»
Screw case is saved.
MODE
20.07.2020
16:32
Angle
HISTORY
20.07.2020
16:32
15/07/20
11:18
60 Nm
19
29/06/20
19:12
44 Nm
19
29/03/20
16:27
73°
19
25/02/20
15:30
200 Nm
19
12/01/20
12:54
63°
19
04/01/20
10:13
11 Nm
19
SCREW CASES
SCREW CASE NAME
New screw case
SCH1
A 0 0 0
SCH2
SCH3
SCH4
SCH5
8.3.2.
Editing screw case
20.07.2020
16:32
20.07.2020
16:32
Peak: ---
Data transfer
Workflow
0
Screw cases
Nm
Settings
Info
1. Press the down function button or OK, enter the password if necessary and con-
firm with OK.
2. Select "Screw cases" and confirm with OK or the down function button.
3. Select screw case to be edited and confirm with OK.
4. Select "Edit" and confirm with OK or the down function button.
5. Edit name or confirm with OK or the down function button.
6. Edit settings.
8.3.3.
Calling up screw case
20.07.2020
16:32
20.07.2020
16:32
Peak: ---
Data transfer
Workflow
0
Screw cases
Nm
Settings
Info
1. Press the down function button or OK, enter the password if necessary and con-
firm with OK.
2. Select "Screw cases" and confirm with OK or the down function button.
3. Select desired screw case and confirm with OK.
4. Select "Activate" and confirm with OK or the down function button.
5. Carry out tightening procedure according to the screw case.
8.3.4.
Deleting screw case
20.07.2020
16:32
20.07.2020
16:32
Peak: ---
Data transfer
Workflow
0
Screw cases
Nm
Settings
Info
1. Press the down function button or OK, enter the password if necessary and con-
firm with OK.
2. Select "Screw cases" and confirm with OK or the down function button.
3. Select screw case to be deleted.
4. Press the down function button.
5. Confirm deletion with OK or the down function button.
8.4.
WORKFLOW
8.4.1.
Creating a workflow
20.07.2020
16:32
20.07.2020
16:32
Peak: ---
Data transfer
Workflow
0
Screw cases
Nm
Settings
Info
FILTER MEASUREMENT METHOD
FILTER MEASUREMENT METHOD
SCH1
SCH2
Torque
Target
Target
Monitoring
Monitoring
Angle
SCH3
SCH4
Target
Target
Monitoring
Monitoring
SCH5
SCH6
Target
Target
Monitoring
Monitoring
i
A maximum of 10 workflows can be saved.
ü Screw cases are created.
1. Press the down function button or OK, enter the password if necessary and con-
firm with OK.
2. Select "Workflow" and confirm with OK or the down function button.
3. Select "New workflow" and confirm with OK.
4. Assign a name with a maximum of four characters using the up, down, left and
right buttons.
5. Confirm with OK or the down function button.
6. Select with the left and right buttons whether the workflow is to be password-
protected and confirm with OK or the down function button.
i
In the case of active Workflow PWD: password must be entered in the case of
an incorrectly executed tightening procedure.
»
Workflow created.
7. Select position for screw case to be created and confirm with OK.
8. Select "Torque" or "Angle" to filter saved screw cases and confirm with OK or the
down function button.
9. Select "Screw cases" and add to workflow by pressing OK. Details about the screw
case can be displayed with the down function button.
10. Add further Screw cases.
11. After completion, press the up function button to save the Workflow.
8.4.2.
Editing workflow
20.07.2020
16:32
20.07.2020
16:32
Peak: ---
Data transfer
Workflow
0
Screw cases
Nm
Settings
Info
1. Press the down function button or OK, enter the password if necessary and con-
firm with OK.
2. Select "Workflow" and confirm with OK or the down function button.
3. Select the Workflow to be edited and confirm with OK.
4. Select "Edit" and confirm with OK or the down function button.
SCREW CASES
SCREW CASES
New screw case
Activate
SCH1
Edit
SCH2
Details
SCH3
SCH4
SCH5
SCREW CASES
SCREW CASES
New screw case
Activate
SCH1
Edit
SCH2
Details
SCH3
SCH4
SCH5
SCREW CASES
20.07.2020
16:32
New screw case
SCH1
Delete screw case "xxxx"?
SCH2
SCH3
SCH4
SCH5
WORKFLOW
WORKFLOW NAME
New workflow
ARB1
A 0 0 0
ARB2
ARB3
ARB4
ARB5
WORKFLOW
Password
Free position
Free position
No
Free position
Free position
Free position
Free position
WORKFLOW
WORKFLOW