Descargar Imprimir esta página

Balluff BTL7-P511-M S115 Serie Manual De Instrucciones página 36

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

BTL7-P511-M _ _ _ _ -BE/BF/CE/ZE/ZF-S32/S115/KA _ _ /FA _ _
Magnetostrictive Linear Position Sensor — Rod Style
4
Installation and connection (continued)
4.5
Shielding and cable routing
Defined ground!
The BTL and the control cabinet must be at the
same ground potential.
Shielding
To ensure electromagnetic compatibility (EMC), observe
the following:
Connect the BTL and controller using a shielded cable.
Shielding: Copper filament braided, at least 85%
coverage
Connector version: Shield is interally connected to
connector housing.
Cable version: On the BTL side the cable shielding is
connected to the housing.
Ground the cable shielding on the controller side
(connect with the protective earth conductor).
Magnetic fields
The position measuring system is a magnetostrictive
system. Ensure that there is sufficient distance between
the BTL, holding cylinder and strong, external magnetic
fields.
Cable routing
Do not route the cable between the BTL, controller, and
power supply near high voltage cables (inductive stray
noise is possible).
The cable must be routed tension-free.
Bending radius for fixed cable
The bending radius for a fixed cable must be at least five
times the cable diameter.
Cable length
BTL7-P...
Max. 500 m
Prerequisite: Construction, shielding and routing preclude the effect of any
1)
external noise fields. Required cable cross-section ≥ 0.6 mm
≤ AWG19.
Tab. 4-4:
Cable length BTL7
12
english
1)
or
2

Publicidad

loading

Este manual también es adecuado para:

Btl7-p511-m bf serieBtl7-p511-m ce serieBtl7-p511-m ze serieBtl7-p511-m zf-s32 serieBtl7-p511-m be serieBtl7-p511-m ka serie ... Mostrar todo