Setting The Shielding Gas Volume; Introducing The Wire - Abicor Binzel ABIROB A Serie Instructivo De Servicio

Ocultar thumbs Ver también para ABIROB A Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

®
ABIROB
A

6.5 Setting the shielding gas volume

6.6 Introducing the wire

7 Operation
NOTICE
• The type and amount of shielding gas used depend on the welding task
and the gas nozzle geometry.
• To prevent the shielding gas supply from becoming clogged by
impurities, briefly open the cylinder valve before connecting the cylinder.
This will expel any impurities that may be present.
• Make all shielding gas connections gas-tight.
1 Connect the shielding gas cylinder to the wire feeder.
2 Set the gas quantity on the shielding gas cylinder's pressure reducer.
NOTICE
• Each time the wire is changed, make sure that the start of the wire is free
of burrs.
1 Insert the wire in the wire feeder as specified by the manufacturer.
2 Press the 'zero-current wire feed' button on the wire feeder.
DANGER
Shortness of breath and poisoning caused by inhaling
phosgene gas
When welding workpieces that have been degreased with chlorinated
solvents, phosgene gas is formed.
• Do not inhale fumes and vapours.
• Ensure a sufficient supply of fresh air.
• Rinse workpieces with clean water prior to welding.
• Do not place degreasing baths containing chlorine in the vicinity of the
welding area.
7 Operation
EN - 15

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Abirob a360Abirob a500

Tabla de contenido