FES-200
NOTICE
• Before performing any maintenance and cleaning work, the necessary safety measures must be
• Maintenance and cleaning work on the fume extraction system may only be carried out in areas with
• Maintenance and cleaning work may only be carried out by qualified personnel (in Germany see
• Always wear your personal protective equipment when performing maintenance and cleaning work.
• The personal protective equipment includes protective clothing, safety goggles, respirator mask

9.1 Inspection intervals

NOTICE
• The maintenance intervals given are standard values and refer to single-shift operation.
• We recommend to record the inspections. The date of the inspection, the detected defects and the
Check the following:
Every day by the user
Visual inspection:
Fume extraction system or parts of it
damaged?
Visual inspection:
Cable connections damaged?
Filling level of the dust collecting drawer
 5.1 Dedusting the filter on
page EN-13
Tab. 7
Inspection intervals
taken.
locally filtered forced ventilation.
TRBS 1203).
class P3, protective gloves and safety shoes.
name of the inspector must be recorded.
Every month by qualified personnel
Visual inspection:
Filter untight? (trails of dust or deposits on the air
outlets)
Visual inspection:
Function of the minimum air volume flow control
guaranteed?
Seal the air inlet. As soon as the value on the
manometer indicator increases, an acoustic
signal sounds.
9 Maintenance and cleaning
Every year by qualified
personnel
Visual inspection:
Dust in the turbine area, remove dust
using an industrial vacuum cleaner or a
damp disposable cloth.
Visual inspection of the filter cartridge
Check the tightness
EN - 19