9 Maintenance and cleaning

9 Maintenance and cleaning
Regular ongoing maintenance and cleaning are prerequisites for a long service life and trouble-free operation.
DANGER
Risk of injury due to unexpected start
The following instructions must be adhered to during all maintenance, servicing, assembly, disassembly and repair work:
• Switch off the extraction system.
• Close off the compressed air supply.
• Disconnect all electrical connections.
WARNING
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
WARNING
Risk of crushing
Limbs may be drawn into the device and crushed.
• Keep your hands out of the danger zone.
NOTICE
• Take appropriate precautions before conducting maintenance and cleaning work.
• Maintenance and cleaning work must only be carried out on the extraction system in areas with locally filtered forced
ventilation.
• Only qualified personnel are permitted to perform work on the device or system.
• Check and wear your personal protective equipment.
9.1 Inspection intervals
We recommend splitting cleaning into two parts. The first part involves emptying the dust from the collecting drawer.
Regularly emptying out the dust can extend the service life of the filter cartridge. The second part involves the electrical and
mechanical maintenance of the filter system. The maintenance cycle is determined by the work environment and by the length
of the scheduled intervals between maintenance of the devices. The maintenance cycle is usually three months.
If the device is operated for more than 8 hours a day, the maintenance intervals should be changed as needed. Regular
maintenance keeps the device in good visual condition and good working order.
NOTICE
• The specified maintenance intervals are standard values and refer to single-shift operation.
• We recommend recording the inspections. The date of the inspection, the detected defects and the name of the
inspector must be recorded.
EN - 16
xFUME VAC ADVANCED
BAL.0731.0 • 2019-09-18