1
2
3
42
5-17
5-18
5-18b
5-19
5-20
Operation
5.4
Weight application
The following weight types and application
methods are available:
- Clip-on weights.
• Always apply by hand at 12 o'clock (Figure
5-17).
• The tab should be fi tted on the rim edge. Use the
weight pliers to correctly position it.
- Stick-on weights.
• Apply with arm gauge, in case of Alu 1P, Alu 2P and
Alu 3P (Figure 5-18).
• Apply by hand at 12 o'clock in all other cases
(Figure 5-18b).
Note: With STATIC balancing mode, always apply
the weight at 12 o'clock on the rim centre line. If
not possible, split the weights evenly and apply on
another surface of the rim (symmetrical to the rim
centre line).
Note: In STATIC balancing modes, only the left
hand display is used.
After wheel run, look at the rotation indicators for
the left plane of the wheel (1, Fig. 5-19):
• Slowly rotate the wheel by hand (e.g.
anticlockwise).
As the correct angle position is reached a further
indicator lights up.
Note: When the correct angle is reached, the WAP
indicator will also light up (2-Fig. 5-20).
The weight to be applied in that plane is shown on
the display.
If the wheel has been pushed too far, only the
indicators of the other half will come ON (3-Fig.
5-20).