2610051885.qxp_CM10GD 12/3/18 8:49 AM Page 26
▶ 0° Bevel Stop – Adjustment
Procedure
power
source
assembly, adjustments or repairs.
▼ ADjUSTING 0° BEVEL STOP
(BLADE 90° TO TABLE)
1. Pull up the bevel lock lever to loosen.
2. Loosen bolt heads "A" and "B" using a
10mm open end wrench or socket (with
socket wrench). Loosen bolts at least one
full turn (see Figure 23).
3. Loosen set screw "D" using the 4mm end of
the 6/4mm hex key (provided with tool, but
Adjustments
To avoid possible injury,
disconnect plug from
before
performing
any
Adjusting Bevel Stops
Figure 23
may also use a standard 4mm hex key).
Loosen screw at least three full turns.
4. Place combination square on table and
against blade (see Figure 22).
5. Using the 4mm end of hex key, turn set
screw "C" and watch the saw blade tilt.
Turn screw "C" until the blade is aligned
(full contact) with the square's body's edge.
After aligning, remove hex key.
6. Tighten set screw "D" using 4mm hex key.
7. Tighten bolt heads "A" and "B" using 10mm
open end wrench.
8. Adjust bevel scale pointers (item 36 – page
12) to be in line with the bevel scale's 0°
lines.
9. Push down the bevel lock lever to lock.