Reactivating Batteries - Fronius Acctiva Smart 25 A Manual De Instrucciones

Ocultar thumbs Ver también para Acctiva Smart 25 A:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 169
Reactivating bat-
teries
Danger of deep-discharged batteries freezing at 0 °C (32 °F).
A frozen battery can become damaged.
► Before starting refresh charging, ensure that the acid in the battery to be refreshed is
1
5
The charger automatically recognises the battery and starts the charging process after 5
seconds.
70
NOTE!
not frozen.
Plug in charger mains plug
2
3
4
Connect the battery - the de-energised charging leads mean there are no sparks when
connecting to the battery, even if the charger is already connected to the mains supply.
Connect the red charging lead to the positive pole (+) of the battery
-
-
Connect the black charging lead to the negative pole (-) of the battery
Select Refresh mode using the up/down keys.
Use the Menu key to select the "Ah" or "Battery type" setting.
Use the Up/Down keys to enter the required value (e.g. 100
Ah or "Wet" battery type).
-
A set of four bars shows the state of
charge of the battery (e.g. three bars
represent a state of charge of 80%).
(Shown symbolically; accurate voltage
indicator: roughly 14-16 V)
-
All four bars are continuously display-
ed.
-
The state of charge is 100%.
-
The battery is ready to use.
-
The battery may remain connected to
the charger under certain conditions
-
Conservation charging counteracts
battery self discharge.
*)
.

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Acctiva professional 35 a

Tabla de contenido