Connecting The Cable Assembly - Abicor Binzel ABIPLAS WELD CT Serie Manual De Instrucciones

Antorcha de soldadura
Ocultar thumbs Ver también para ABIPLAS WELD CT Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

®
ABIPLAS
WELD CT
11 Position the cold-wire feeder (12) and tighten the knurled screw (11).

6.5 Connecting the cable assembly

CAUTION
Mechanical hazard
A loose torch body can result in a mechanical hazard.
• Check that the torch body and cable assembly are firmly attached.
6.6 Attaching the connector to the device
1 Join the welding cable plug and socket at the power source and lock them.
2 Connect the emergency stop cable, pilot power source and power source.
6.7 Mounting the wire conduit and liner
7
1
Guide tube
2
Wire conduit
3
Nut M10 × 1
Fig. 7
Mounting the wire conduit and liner
NOTICE
• Install the wire guide up to the torch without any gaps to avoid possible faults and errors.
1 Guide the sharpened liner through the wire conduit (2).
BAL.0128 • 2019-09-04
6
4
Retaining nipple
5
Guide
6 Putting into operation
1
5
6
Cold-wire tube
7
Feeding nozzle
2
3
4
EN - 15