Operating Instructions
Lubricant Distribution within the Metering Device, continuation
Fig. 15
Phase 5 & 6: Metering piston A supplies V1, Control piston A supplies V2
Phase 5
In phase 5, control piston C has reached its final position
on the left side.
Thereby it opens the junction channel to the left end of
control piston A and metering piston A.
Now the lubricant pressure P is at the left end of control
piston A and metering piston A.
Due to the larger diameter, lubricant pressure P first
moves the metering piston A (black arrow) to the right and
then supplies the enclosed lubricant on the right side of
metering piston A to outlet 2 (V1).
Notes:
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Operation, continuation
Phase 6
When metering piston A reaches its final position on the
right side, lubricant pressure P moves the control piston A
(black arrow) to the right and additionally supplies the en-
closed lubricant on the right side of control piston A to out-
let 2 (V2).
The total output on outlet 2 is the output of metering pis-
ton A and control piston A (V1 + V2).
NOTE
The upper figure shows the transition from
phase 5 to phase 6.
Fig. 12 and fig. 13 (see page 9) show ex-
emplary schematics of the movements of
6001a02
metering and control pistons.