User Manual
Operating Instructions
Pressure Plastic Tubes and High-pressure Hoses
Pressure plastic tubes Ø 6 x 1.5 mm
Use the pressure plastic tubes only in the low-pressure
area, i.e. between secondary metering device and lubrica-
tion point.
High-pressure hose NW 4.1 x 2.3 mm
Fig. 7
Preassembly of threaded sleeves and hose studs on the
high-pressure hose
1 -
Threaded sleeve
2 -
High-pressure hose NW 4.1 x 2.3 mm
3 -
Hose stud
Fig. 8
Preassembly of threaded sleeve by means of adjusting
gauge
1 -
Threaded sleeve
2 -
High-pressure hose NW 4.1 x 2.3 mm
3 -
Adjusting gauge 432-23077-1
Page 6 of 26
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Installation, continuation
Use the high-pressure hose in the high-pressure area, i.e.
between the pump, main metering device and secondary
metering devices.
Adhere to the pressures and bending radiuses mentioned
in the chapter "Technical Data" when installing the parts
and operating the device.
Installing the threaded sleeves and hose studs on the
high-pressure hose
Screw threaded sleeve, item 1 Fig. 7, counterclockwise
onto high-pressure plastic hose 2 until illustrated dimen-
sion of 11 mm is reached. Then screw hose stud 3 into
threaded sleeve 1.
1028a96
1029a96
NOTE
Adhere to the pressures and bending radi-
uses mentioned in the chapter "Technical
Data" when installing the parts and operat-
ing the device.
6001a02
IMPORTANT
Before screwing the parts 1 and 3, rub
them with oil.
NOTE
6001a02
The outside diameter of the high-pressure
hose may show variations in dimension. In
such a case, press the threaded sleeve 1
at the end where it will be screwed onto
the high-pressure hose so that it becomes
oval in shape (1 to 2 mm). This will prevent
the high-pressure plastic hose from being
pushed out of the sleeve when the hose
stud is screwed.
NOTE
When using the special adjusting gauge
432-23077-1 (see Parts Catalog) screw
threaded sleeve counterclockwise onto
high-pressure plastic hose until the gauge
6001a02
inserted in the sleeve begins to rise.
2.2A-20003-B07