Hydraulic Unit (B); Operating Instructions; Putting Into Operation - Rothenberger ROWELD P 160 B Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
3.1.2
Hydraulic unit
1
filler neck and dip stick
2
fast-on connector
3
relief valve
4
fast-on coupling sleeve
The hydraulic unit allows the operator to operate the welding machine and perform the functions
indicated by the following symbols:
To close the clamps press the control lever to the left. The moving and pressure
build-up speed dependent on the angle of rotation
To open the clamps press the control lever to the right. The moving speed de-
pendent on the angle of rotation
Pressure adjusting valve for milling pressure, beat forming pressure, heating
pressure and cooling pressure. The manometer provides information on the
regulated pressure
Pressure relief valve. Anti-clockwise turn can lowered the pressure. The lowering
speed dependent from the number of turns. Right turn pressure hold
3.2

Operating instructions

In accordance with national or EU ordinances and guidelines, e. g. DVS 2212, Section I,
only duly qualified and authorised personnel are allowed to operate the ROWELD weld-
ing machines!
Only trained and authorised welders are allowed to operate the machine!
3.2.1

Putting into operation

Please read through the operating instructions and safety instructions attentively
before you put the butt fusion welding machine into operation!
Do not use the heating element in explosive environments or bring it into contact
with easily flammable materials!
Stay a safe distance away from the machine. Do not stand or reach into the ma-
chine. Keep other people away from the work area!
Before every start-up, check the oil level of the hydraulic unit. The oil level must be
between the min. and max. marking on dipstick in the oil filler cap. If necessary, add
HLP 46 hydraulic oil!
Transport and set the hydraulic unit only in a horizontal position. If it is set at an
angle, oil escapes from the vented plugs with the dipstick!
Connect the hydraulic unit to the basic unit with both hydraulic hoses.
Protect the quick couplings from contamination. Replace leaky couplings immediately!
Connect the trimmer unit, hydraulic unit and heating plate mains plugs to the power out-
let/supply specified on the type plates.
For P160-250/5-8B:
The red "Stand by" diode on the heating element lights up, which means: voltage is being
applied. Switch on the heating element on the hand grip using the large press-button (lights
up green) and set the desired temperature using the "+" or "-" button (160° C to 285° C /
320° F to 545° F).
16
5
mains cable
6
manometer
7
control lever, left-close- right-open
8
pressure adjustment valve
ENGLISH
(B)

Publicidad

Tabla de contenido
loading

Tabla de contenido