ALARM DESCRIPTIONS

NOTE
The alarms shown are both instrument inner alarms (2, Fig. D) and AIA control board transmission line inner alarms
indifferently.
WARNING!
The alarms are shown for up to 5 seconds. Then the alarm is stored in the B_BOX (see the Display Function
Description paragraph).
The instrument inner alarms are shown also in the ALARM LIST (refer to ALARM.01 and ALARM.02 in Display
Function Description paragraph).
The instrument inner alarms are indicated by the name "ALARM" (6, Fig. I) and by some symbols which identify the source (2) and
the seriousness (1) of the alarm. The visualization shown on the second line of the text identifi es the alarm description (3, Fig. I).
For some serious alarms, the machine will be automatically shutdown. In this case the counter (5, Fig. I) resets after a countdown of
20 seconds, then a message appears (4).
In the alarm indications, the seriousness symbol can be different:
-
Alarm which does not compromise the machine operation. Check/replace the component which caused the alarm.
-
Serious alarm which does not cause the machine shutdown. Contact a Advance Service Center.
Serious alarms which causes the machine shutdown. Contact a Advance Service Center.
-
STOP
The instrument inner alarms recognized and shown on the display (17, Fig. D) are shown below:
Shorted fuel level sensor (13, Fig. I)
Open fuel level sensor (12, Fig. I)
Engine coolant overtemperature (11, Fig. I) (the engine is automatically shut-off)
Engine oil low pressure (14, Fig. I) (the engine is automatically shut-off)
Water in fuel (15, Fig. I)
Hydraulic oil overtemperature (16, Fig. I)
Open or disconnected engine coolant temperature sensor (17, Fig. I)
Shorted coolant temperature sensor (18, Fig. I)
Open or disconnected engine oil pressure sensor (19, Fig. I)
The above-mentioned alarms are also indicated by the activation of the relevant warning lights shown in Description of the Control
Area paragraph.
The AIA control board data transmission line inner alarms are indicated by the general message "SYSCODE" (9, Fig. I) plus a
2-digit code (10) which specifi cally represents the alarm and must be communicated to Advance Service Center. The alarms are
shown below:
SYSCODE.99: The control board (AIA) is disconnected
SYSCODE.08: There was no hopper sensor signal at the lifting
SYSCODE.07: The engine speed sensor was not detected at machine start-up

ACCESSORIES/OPTIONS

In addition to the standard components, the machine can be equipped with the following accessories/options, according to the
machine specifi c use:
3rd broom
Brooms with harder and softer bristles
Camera kit
High-pressure washing system
Ready for radio installation
Rear manual suction pipe
Climate control system
Snow equipment prefi tting
Salt spreader kit
Snow brush kit
20