Work Instructions And Safety Precautions - Festo 8082795 Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Storing/Conveyor station

5 Work Instructions and Safety Precautions

General
Trainees should only work with the circuits under the supervision of an instructor.
Electrical devices (e.g. power packs, compressors and hydraulic units) may only be operated in training
rooms that are equipped with residual current devices (RCD).
Observe the specifications included in the technical data for the individual components, and in
particular all safety instructions!
Malfunctions which might impair safety must not be generated when the device is operated for training
purposes.
Wear personal safety equipment (safety goggles, safety shoes) when working on circuits.
Mechanical system
Switch off the power supply.
Switch off both the operating power and the control power before working on the circuit.
Only reach into the setup when it is at a complete standstill.
Be aware of potential overtravel times for the actuators.
Mount all of the components securely on the profile plate.
Risk of injury during troubleshooting.
Use a tool such as a screwdriver for actuating sensors.
Set all components up so that activation of switches and interrupters is not made difficult.
Follow the instructions about positioning the components.
Electrical Safety
Risk of death when the PE conductor is interrupted!
The PE conductor (yellow-green) must not be interrupted, either inside or outside of the device.
The insulation of the protective conductor must never be damaged or removed.
Establishing and disconnecting electrical connections
Electrical connections may only be established in the absence of voltage.
Electrical connections may only be disconnected in the absence of voltage.
The power supply unit must only be operated using a power supply with a PE conductor.
46
© Festo Didactic 8083287

Publicidad

Tabla de contenido
loading

Tabla de contenido