Programming station
®
The MPS
may only be used:
For its intended purpose
When its safety functions are in perfect condition.

5 Work and safety instructions

General
Trainees should only work with the circuits under the supervision of an instructor.
Electrical devices (e.g. power packs, compressors and hydraulic units) may only be operated in training
rooms that are equipped with residual current devices (RCDs).
Observe the specifications included in the technical data for the individual components, and in
particular all safety instructions!
Malfunctions which might impair safety must not be generated when the device is operated for training
purposes.
Wear personal safety equipment (safety glasses, safety shoes) when working on circuits.
Mechanical safety
Switch off the power supply!
Switch off the working and control power before working on the circuit.
Only reach into the setup when it's at a complete standstill.
Be aware of potential overtravel times for the drives.
Mount all of the components securely on the profile plate.
Make sure that limit valves are not actuated from the front.
Risk of injury during troubleshooting!
Use a tool such as a screwdriver to actuate limit valves.
Set all components up so that it's easy to activate the switches and interrupters.
Follow the instructions about positioning the components.
28
Malfunctions which may impair safety must be eliminated immediately!