2.4 Information displayed during operation
Small green LED
en
Small yellow LED
Large green and red LEDs
2.5 PT 10 quick check device in cardboard box - items supplied
1
PT 10 quick check device
1
PTA 70 tripod adapter
1
PTA 45 tripod head
1
PTA 40 tripod column
1
Disc or accessory
1
Mains adaptor
1
Operating instructions
1
Manufacturer's certificate
2.6 PT 10 - associated items in separate box
1
PTA 10 optical level with camera
2.7 PT 10 - associated items in Hilti toolbox
1
PTA 20 calibration tool
1
Mains adaptor
12
The green LED doesn't light.
The green LED doesn't light.
The green LED lights con-
stantly.
The green LED blinks.
The yellow LED doesn't light.
The yellow LED doesn't light.
Only one yellow LED lights.
Both LEDs light constantly.
Both yellow LEDs blink.
The green LED lights.
The red LED lights.
The tool is switched off.
The tool is not connected to the electric
supply.
Beam search for the laser beam from
the tool under test is active. After
searching in beam search mode
unsuccessfully for 2 minutes, the
PT 10 quick check device reverts
automatically to standby mode.
Ready mode.
The laser beam is not aimed at the
opening in the filter unit and therefore
not at the camera. Use the fine
adjustment screws to rotate the optical
level until both yellow LEDs light
constantly.
The laser beam is not striking the cam-
era. Check that the Hilti laser tool is
switched on.
The laser beam is striking the camera
only partially. Use the fine adjustment
screws to rotate the optical level until
both yellow LEDs light constantly.
The laser beam is striking the camera
and the tool is ready to begin measur-
ing.
Information displayed while measuring
is in progress.
Result of test: The laser tool under test
is within the specified accuracy.
Result of test: The laser tool under test
is not within the specified accuracy and
must be returned to a Hilti service cen-
ter for calibration.