Operation - Hilti PT 10 Manual De Instrucciones

Ocultar thumbs Ver también para PT 10:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
3.
Screw the PTA 70 tripod adapter onto the tripod
head. Rotate the tripod adapter until the designation
"PTA 70" can be read from the front and then use the
hex. socket wrench supplied to tighten the screw.
6.1.2 Fitting the optical level 7
1.
Unscrew the two wing screws and open the rear
cover on the concrete base.
2.
Place the PTA 10 optical level on the raised part of
the concrete base and secure it with the adjusting
screw provided.
NOTE Take care to ensure that the filter unit is
directed toward the tripod head.
3.
Close the rear cover on the concrete base and
tighten the two wing screws.

7 Operation

7.1 Mounting the laser tool on the tripod adapter
7.1.1 Mounting point lasers, rotating lasers
or multidirectional lasers on the tripod
adapter 9 10
1.
Screw the PTA 70 tripod adapter onto the tripod
head.
2.
Place the Hilti laser tool under test on the adapter
plate and switch it on.
3.
Use the crank to adjust the height of the Hilti laser
tool so that the laser beam is aimed at the center of
the crosshairs in the middle of the filter disc.
7.1.2 Mounting the laser tool on the adapter plate
for the PP 10 and PP 11 pipe lasers
1.
Screw the PPA 73 tripod adapter onto the tripod
head.
2.
Place the pipe laser on the tripod adapter and switch
it on.
3.
Use the crank to adjust the height of the Hilti laser
tool so that the laser beam is aimed at the center of
the crosshairs in the middle of filter disc.
7.1.3 Switching on 11
Switch on the PT 10 quick check device.
7.2 Setting the accuracy class 11
1.
Select the applicable accuracy class 1-9 according
to the table of Hilti tools.
2.
Press the +/- buttons until the corresponding accur-
acy class appears.
6.1.3 Electrical connections 8
1.
Connect the cable from the PTA 10 optical level to
the connector on the rear of the concrete base.
2.
Connect the supply cord to the rear of the concrete
base.
3.
Plug the supply cord into the power outlet.
6.1.4 Setting up the PT 10 quick check device in
the horizontal plane 6 8
NOTE
The PT 10 must be set up in the horizontal plane before
use. First use the bubble level on the tripod adapter as
a reference and then the bubble level incorporated in
the optical level. The bubbles of both levels must be
centered (in the inner circle) before the tool can be used
for measuring. Calibrate the PT 10 quick check device
before use.
7.3 Filter setting 11
1.
Select filter setting I or II according to the table of
Hilti tools.
2.
Move the switch on the filter disc to the correspond-
ing position.
7.4 Adjusting the camera 12 13
The position of the laser beam on the camera lens is
indicated by the yellow LEDs.
If neither of the yellow LEDs light up or only one LED
lights, turn the fine adjustment screw on the optical level
until the laser beam is found.
Both yellow LEDs light up as soon as the laser beam
strikes the camera. At the same time, the "Start meas-
uring" button becomes active and the device is ready to
begin the test.
7.5 Measuring 14
NOTE
Do not touch or move the PT 10 quick check device
while measuring is in progress. An error message will be
displayed in the event of vibration.
The PT 10 quick check device is ready to begin meas-
uring as soon as both yellow LEDs light and the "Start
measuring" button is shown to be active.
Press the "Start measuring" button. The measuring op-
eration is indicated by the yellow LEDs blinking and
continues, on average, for approx. 50 seconds.
7.6 Indication of result
NOTE
All 4 directional axes (X, Y) of rotating lasers must always
be tested.
en
15

Publicidad

Tabla de contenido
loading

Tabla de contenido