4-3. Voltmeter/Ammeter Help Displays

.
All directions are in reference to the
front of the unit. All circuitry referred to
is located inside the unit.
1
Help 0 Display
Indicates a short in the thermal protection
circuitry located on the transformer of the
unit. If this display is shown, contact a Fac-
tory Authorized Service Agent.
2
Help1 Display
An SCR overcurrent condition has oc-
curred. Turn power off and back on to cor-
rect condition. If problem continues, con-
tact a Factory Authorized Service Agent.
3
Help2 Display
Indicates an open in the thermal protection
circuitry located on the transformer of the
unit. If this display is shown, contact a Fac-
1
V
HELP
3
V
HELP
5
V
HELP
7
V
HELP
9
V
POL
OM-225 389 Page 26
tory Authorized Service Agent.
4
OVER TEMP XFMR
Indicates the transformer of the unit has
overheated. The unit has shut down to al-
low the fan to cool it (see Section 2-6). Op-
eration will continue when the unit has
cooled.
5
Help 4 Display
Indicates an open in the thermal protection
circuitry located on the rectifier assembly of
the unit. If this display is shown, contact a
Factory Authorized Service Agent.
6
OVER TEMP RECT
Indicates the rectifier assembly of the unit
has overheated. The unit has shut down to
allow the fan to cool it (see Section 2-6). Op-
2
A
0
HELP
4
A
2
OVER
XFMR
6
A
4
OVER
RECT
8
A
9
10
A
ERR
eration will continue when the unit has
cooled.
7
Help 9 Display
Indicates a short in the thermal protection
circuitry located on the rectifier assembly of
the unit. If this display is shown, contact a
Factory Authorized Service Agent.
8
REL RMT
Indicates Remote Output control is acti-
vated. Release Remote Output control to
clear help message.
9
POL ERR
Indicates Output Selector switch is not in
correct position (see Section 3-1).
10 NOT VALID
Indicates a non-allowable set-up on the
front panel.