Connecting Input Power In 208-230 Volt Models; Connecting Input Power In 460/575 Volt Models - Miller Syncrowave 200 Manual Del Propietário Y Guía

Ocultar thumbs Ver también para Syncrowave 200:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2-16. Connecting Input Power In 208-230 Volt Models

'

2-17. Connecting Input Power In 460/575 Volt Models

A. Placing Jumper Links
1
2
Tools Needed:
3/8 in.
1
5
7
L1
L2
2
3
!
Installation must meet all National
and Local Codes − have only quali-
fied persons make this installation.
!
Disconnect and lockout/tagout in-
put power before connecting input
=GND/PE Earth Ground
conductors from unit.
!
Always connect green or green/
yellow
grounding terminal first, and never
to a line terminal.
4
1
Black And White Input Conductor
(L1 And L2)
2
Green Or Green/Yellow Grounding
Conductor
6
3
Input Power Cord.
4
Disconnect Device (switch shown in
1
the OFF position)
5
Disconnect Device Grounding
Terminal
6
Disconnect Device Line Terminals
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1 and L2 to
disconnect device line terminals.
7
Over-Current Protection
Select type and size of over-current
protection using Section 2-15 (fused dis-
connect switch shown).
Close and secure door on disconnect
device. Remove lockout/tagout device,
and place switch in the On position.
Tools Needed:
conductor
to
supply
804 234-C / Ref. 803 766-B
!
Disconnect and lockout/tag-
out input
power
before
installing or moving jumper
links.
Check input voltage available at
site.
Remove cover and left side panel.
1
Jumper Link Label
2
Jumper Links
Move jumper links to match input
voltage.
Install left side panel and cover, or
go on to Section B.
Ref. 804 470-B
OM-225 389 Page 13

Publicidad

Tabla de contenido
loading

Tabla de contenido