To change the application position for the
adhesive weights, follow the instructions
in the service mode "Adhesive weight
application position".
BALANCING
WEIGHT
APPLICATION
CLIP WEIGHTS
- Select the first side to be balanced.
- turn the wheel until the central element
of the corresponding position indicator
lights up.
- apply the indicated balancing weight in
the position of the rim corresponding to
12 o'clock.
WARNING
Check that the system to fix the weight to
the rim is in optimum condition.
A weight which is not fitted properly
or correctly may come off as the wheel
rotates, thus creating a potential danger.
Pressing the
in motion interrupts the wheel spin before
completion and calls up the message StoP.
If the "RPA" (centred position) program
is active, at the end of each balancing
spin the machine stops the wheel in the
position for application of the weight on
the outer sidewall; if this is null the wheel
is locked in the application position of the
inner sidewall.
Pressing the
raised, automatic search for the second side
position is activated.
This function is described at length in the
AUTOMATIC POSITION SEARCH section.
User manual ProLine Truck 150
key while the wheel is
button with the guard
MANUALLY APPLIED ADHESIVE
WEIGHTS
- Select the first side to be balanced.
- turn the wheel until the central element
of the corresponding position indicator
lights up.
- apply the indicated balancing weight in
the position of the rim corresponding to
12 o'clock.
CAUTION
The application position of the adhesive
weight can be changed from 12 o'clock to
6 o'clock by following the instructions in
the chapter "Adhesive weight application
position".
IMPORTANT
If the type of wheel selected is CAR or
SUV, in ALU1 and ALU2 programs the
imbalance displayed by the machine on
the outer sidewall refers to the adhesive
weight centre of gravity at the swinging
unit bearing flange (Fig. 22).
MANUALLY APPLIED ADHESIVE
WEIGHTS WITH LASER DEVICE
ENABLED (IF PROVIDED)
- Select the first side to be balanced.
- turn the wheel until the central element
of the corresponding position indicator
lights up together with the laser line
- apply the indicated balancing weight in
UK
22
103