BTL7-P511-M _ _ _ _ -A/B/Y/Z(8)-S32/S115/S135/KA _ _ /FA _ _
Magnetostrictive Linear Position Sensor – Rod Style
7
Technical data (continued)
7.5

Dimensions, weights

Rod diameter
8 mm or 10.2 mm
Nominal length
For Ø 8 mm
25...1016 mm
For Ø 10.2 mm
25...7620 mm
Weight (depends on
Approx. 2 kg/m
length)
Housing material
Aluminum
Flange material
Stainless steel
Rod material
Stainless steel
Rod wall thickness
For Ø 8 mm
0.9 mm
For Ø 10.2 mm
2 mm
Housing mounting via
M18×1.5 or 3/4"-16UNF
threads
Tightening torque
Max. 100 Nm
7.6

Update rate and clock frequency

The maximum sampling frequency f
current value is available with each sampling, can be found
in the following graphic:
f
in Hz
A,max
Fig. 7-1:
Maximum sampling rate depending on the nominal length
www.balluff.com
, at which a new
A,max
Nominal length in mm
BTL7-...-KA_ _
Cable material
PUR;
cULus 20549
80 °C, 300 V,
internal wiring
Cable temperature
–40...+90°C
Cable diameter
Max. 7 mm
Permissible bending
radius
Fixed routing
≥ 35 mm
Movable
≥ 105 mm
BTL7-...-FA_ _
Cable material
PTFE
No UL approval available
Cable temperature
–55...+200°C
Cable diameter
Max. 7 mm
Permissible bending
radius
Fixed routing
≥ 35 mm
Movable
No permissible bending
radius
The minimum sampling frequency f
(1) 1 magnet
(2) 2...16 magnets
is 62,5 Hz.
A,min
english