Hilti PP 10 Manual De Instrucciones página 33

Ocultar thumbs Ver también para PP 10:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 70
3.
Press the SET button to enter the correct mode.
4.
The laser beam UP / DOWN button and direction
control button can be used to navigate to the
corresponding number. Press the SET button
to confirm the number selected. Press the SET
button to confirm the code as soon as the four
desired digits are displayed in the "code" area of
en
the display.
5.
The display then returns to the previous mode.
The security code can then be activated ("on"
by pressing the SET button) or deactivated later
("off" by pressing the SET button again).
The tool then returns to the normal operating
mode.
7.18.3 Entering the name of the company
These instructions describe how to enter or change
the name of the company. A maximum of 32 charac-
ters (16 characters in 2 rows) can be entered.
1.
Press the ON / OFF button and the LOCK button
at the same time.
The set values are shown in the display.
2.
Use the laser beam UP / DOWN button to move
to the "change name" line.
3.
Press the SET button to enter the correct mode.
4.
Use the laser beam UP / DOWN button and
direction control button to navigate to the cor-
responding characters / digits. Press the SET
button to confirm the character selected. Press
the SET button to confirm the entry as soon as
the correct name / designation is displayed.
The tool then returns to the normal operating
mode.
7.19 Checking the tool's accuracy 13
1.
Set the laser to an inclination of 0.000%.
2.
Set up a leveling staff at a distance of 1m and a
second leveling staff at a distance of 60m. Note
the heights at which the laser beam strikes the
staffs.
28
Printed: 07.07.2013 | Doc-Nr: PUB / 5070160 / 000 / 00
3.
Set up an optical level in the middle between
the two leveling staffs and read the heights from
both staffs.
4.
Calculate the difference in height indicated by the
optical level and the rotating laser on staffs 1 and
2. If both values are identical, then the laser tool
is correctly adjusted.
NOTE If the differences X1 and X2 are not equal,
please contact your local Hilti Center or Hilti
representative.
7.20 Working with the PPA 20 remote control
unit
The "lock" function must be deactivated on the laser
tool.
The PPA 20 remote control unit allows you to switch
the laser tool on and off, to activate horizontal align-
ment and to select the laser beam mode remotely.
Press the applicable button on the remote control unit
to activate the corresponding function.
7.21 Working in standby mode
To switch the laser tool off, the ON / OFF button on
the laser tool must be pressed.
Only the laser beam is switched off by the ON / OFF
button on the remote control unit. The laser tool
remains in standby mode (the standby LED on the
tool blinks slowly).
When using the remote control unit, point the signal
transmission aperture on the remote control unit
toward the receiving window on the laser tool.
When switching the laser on, press and hold the ON
/ OFF button for 2 seconds.
NOTE
If the pipe laser is moved, it can no longer be switched
on by the remote control unit. The message "Error"
is shown on the display of the pipe laser and the laser
beam blinks slowly.
Press the ON / OFF button on the pipe laser and check
that the laser is set up correctly.

Publicidad