Electrical Connection; A - Electrical Connection Of The Oven - OEM VOLTAIRE Manual De Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

VOLTAIRE
Installation and connections
3.4 - ELECTRICAL CONNECTION (Fig. 6)
• The power feed line should be provided with a
suitable omnipolar DISCONNECTING SWITCH
(automatic thermomagnetic switch or differential)
placed before the control unit main switch, with
a minimum contact opening of 3 mm.
• The earthing system should comply with the local
electric regulations in force.
• Electric power supply cables shall be dimen-
sioned depending on the highest power rate be-
ing needed by the oven and in such a way that
the total voltage drop is lower than 2%, under full
load conditions.
• The specifications of the electric power line
should correspond to the specifications of the
identification plate and to those mentioned in
the technical specifications table that can be
consulted in the first part of this booklet.
Before connecting the machine with the electric
line, make sure that the DISCONNECTING SWITCH
is disconnected (line not energized).

3.4.a - Electrical connection of the oven

• Remove the knobs (1).
• Loosen the screws (2) and remove the panel (3).
• Connect a power cable (4) properly sized depending
on the absorption of the oven to terminal (5) connect-
ing the phase and neutral terminals F1 and F2 and the
earth to terminal T.
• Plug the power cord (4) in the suitable cable gland
conduit (6) and connect it to the mains switch located
upstream of the furnace.
The line disconnector positioned upstream of the
oven must be in an easily accessible area.
• Reassembling of the panel (3).
DANGER
DANGER
IMPORTANT
FIG. 6
GB - 19

Publicidad

Tabla de contenido
loading

Tabla de contenido