Malfunction, Causes And Remedies - OEM VOLTAIRE Manual De Uso Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

5.5 - MALFUNCTION, CAUSES AND REMEDIES

PROBLEMS
Gas smell:
Smell of unburned gas:
The oven gives condensa-
tion:
T h e p i l o t b u r n e r i s
switched off / switching
off the main burner:
Irregular combustion:
Backfire, switching on the
nozzle:
The pilot burner does not
light:
Ignition delay "with out-
bursts and burners":
The main burner does not
light on, while pilot burner
remains on:
The oven doesn't switch
on:
GB - 30
CAUSES
It is caused by losses in the cir-
cuit of piping.
Can be caused by obstructions
in the circuit of hot smoke.
Can be caused by obstruction
of the stack or from heights and
sections not proportionate to the
oven.
Check that the pilot flame is
enough to heat the thermocou-
ple.
This happens when the burner
flames are too high, too low or
yellow.
Ceramic plates are not adjacent
or broken.
This can be caused by the pres-
ence of air in the gas circuit,
especially after a period of inac-
tivity.
RIMEDIES
You must check the hoses (external) with
special products (soap) and not directly
with the flame (fire or explosion especially
with GPL).
Check that the flue is not obstructed and
that the section and height of the same
are suitable for the oven.
Check that the gas consumption is not
excessive.
Check the condition of the combustion.
Check that the oven is not operating at low
temperature.
Check the regularity of the burner flames.
If necessary, adjust the scope of the pilot
burner.
Ensure that the solenoid valve is working.
In the first two cases, control the gas pres-
sure (the outlet pressure of the ramp) and
the diameter of the nozzles.
In the third case verify the cleanliness of
the platelets (which did not have clogged
the holes) of the burners and internal
cleaning.
Turn off the gas supply and provide the
correct placement or replacement of bro-
ken plates.
If the gas does not arrive, check that the
nozzle hole is not blocked. Incorrect po-
sitioning of the electrode.
Check the gas pressure.
Make sure the burner ignition is not too
far from the main burners and the ignition
flame is not too low.
Check the main switch; the control ther-
mostat and safety thermostat, they must
be attached and functioning.
Make sure there is power and verify that
there is continuity in the coil of the sole-
noid.
Check for electrical connection.
Check that the main switch is plugged
Call Technical Support Service.
VOLTAIRE
Functioning

Publicidad

Tabla de contenido
loading

Tabla de contenido