Operating instructions SATAjet 4000 B RP/HVLP (DIGITAL)
EN
• Installation of a battery other than the CR 1632 Renata!
When exchanging the battery, it is recommended to also replace the
sealing of the battery compartment!
7.
Use
• Use only solvent-resistant, antistatic, undamaged and technically flaw-
less compressed air hoses with a permanent pressure resistance of
minimum 10 bar, e.g. Art. No. 53090!
The following requirements must be fulfilled:
• Use a compressed air connection G 1/4 a or a suitable SATA connec-
tion nipple.
• Ensure minimum compressed air volume (air consumption) and pres-
sure (recommended spray gun inlet pressure) according to chapter 2.
• Use clean compressed air, e.g. by installing the SATA filter 484, Art.
No. 92320
• Use an air hose with minimum 9 mm internal diameter (see warnings),
e.g. Art. No. 53090.
1. Check if all screws [2-1], [2-2], [2-3], [2-4] and [2-5] have been
tightened firmly. Tighten fluid tip [2-1] firmly by hand (14 Nm) accord-
ing to [7-4]. Check if locking screw [2-5] has been firmly tightened
according to [10-1]. Tighten, if necessary.
2. Rinse material passages with suitable cleaning solution [2-6], ob-
serve chapter 8.
3. Adjust air cap: vertical spray fan [2-7], horizontal spray fan [2-8].
4. Insert paint strainer [2-9] and install gravity flow cup [2-10].
5. Fill gravity flow cup (max. 20 mm below upper edge), close with the lid
[2-11] and insert anti-drip device [2-12].
6. Screw connection nipple [2-13] (not included in delivery) onto the air
inlet.
118
Warning! Risk of explosion!
Warning! Risk of explosion!
Notice!