Boiler
Power supply voltage
Frequency
Maximum absorbed electric power
Maximum thermal power interchangeable
Max. temperature flow
Max. pressure flow
Switching time among installations
Insulation class
Protection degree
Wooden boiler or thermo-stove fitting.
Boiler fitting.
Installation fitting
Length
Height
Depth
Weight (dry)
For the proper operation of the KIT-2, it needs a water temperature control system for the alternative heating source (wood-burning thermo-
stove) in order to activate the module when it gets the temperature required.
IMPORTANT: anticipate the installation of KIT-2 near the wood-burning thermo-stove so that the sensor can
detect in a short preriod of the time the heat coming from the wood-burning thermo-stove. If possible, place
the sensor on the pipes inside the thermo-stove and, if necessary lengthen the connection cable between
the sensor and the regulator. These operations must be made with caution in order to avoid the risk of
electric interference in the sensor cable.
Electronic regulator (see drawing D12.3). The electronic regulator is preset with all needed
parameters to the performance of a hydraulic system.
Operation: The diverter valve switch the water flow to the installation when it gets the value established by
the user (by default 45ºC). The water "recirculates" in the exchanger until it reaches a high temperature to
give heat to the installation.
P1
Deviating
valve
D12.2
Instalación
Heat exchanger
P2
Probe
V
Hz
W
Kw
ºC
bar
s
mm
mm
mm
kg
32
INSERT
230
50
<100
40/44
90
3
30
I
IPx40
G ¾"
G ¾"
G ¾"
375
552
185
14
D12.3
SET
ON

Publicidad

loading