Operating Instructions SATAjet 100 B F (RP / HVLP), B P
4. Description
The compressed air required for spraying is supplied at the compressed
air connection. Pull the trigger to the first pressure point to activate the
pre-air control. Continue pulling the trigger to pull the paint needle out of
the fluid tip: the material flows without pressure out of the fluid tip and is
atomised by the compressed air flowing out of the air cap.
5. Scope of Delivery
■ Spray gun with nozzle set B F RP / B F HVLP/ B P and gravity flow cup
■ Tool kit
■ CCS clips
■ Operating Instructions
Alternative version
■ Gravity flow cups made of PVC or aluminium with different capacities
After unpacking, check:
■ Spray gun damaged
■ Complete scope of supply
6. Technical Design
Anti-drip device
[1-1]
Round / flat fan control
[1-2]
[1-3]
Material flow control
[1-4]
Counter nut material flow
control
Air micrometer (aif flow
[1-5]
control knob)
Air micrometer (air flow
[1-6]
control) locking screw
[1-7]
Air piston (not visible)
[1-8]
Compressed air connection
G ¼ „ (male thread)
ColorCode-System (CCS)
[1-9]
6.1. Air micrometer (aif flow control knob)
[3-25] SATA adam 2 (see
chapter 14)
[3-26] Separate pressure gauge
with control device (see
chapter 14)
[1-10] Paint spray gun handle
[1-11] Trigger
[1-12] Nozzle set consisting of air
cap, fluid tip (not visible),
paint needle (not visible)
[1-13] Paint spray gun connection
with QCC
[1-14] Gravity flow cup connection
with QCC
[1-15] Paint strainer (not visible)
[1-16] Gravity flow cup
[1-17] Gravity flow cup lid
[3-27] Separate pressure gauge
without control device (see
chapter 14)
[3-28] Pressure measurement in
compressed air circuit
EN