HF requires an additional license for the AC440. If not purchased, the button is grayed out.
3
MF requires additional license for the AC440. If not purchased, the button is grayed out.
Affinity2.0 – Instructions for Use - EN
Fold an area so that it only shows the label or the buttons of that area.
Unfold an area so that all buttons and labels are visible
Show/hide areas can be found by right mouse clicking on one of the areas.
The visibility of the different areas as well as the space that they take on the
screen is locally saved to the examiner.
List of Defined Protocols allows for selecting a test protocol for the urrent
test session. Right mouse click on a protocol allows the current examiner to
set or deselect a default startup protocol.
Please refer to the Affinity "Additional Information" document for more
information on protocols and protocol setup.
Temporary Setup allows for making temporary changes to the selected
protocol. The changes will be valid for the current session only. After
making the changes and returning to the main screen, the name of the
protocol will be followed by an asterisk (*).
List of historical sessions accesses historical sessions for comparison
purposes. The audiogram of the selected session, indicated by the orange
background, is shown in colours as defined by the used symbol set. All
other audiograms that are selected by check marks show on screen in the
colours as indicated by the text colour of the date and time stamp. Note
that this listing can be resized by dragging the double lines up or down.
Go to Current Session brings you back to the current session.
High Frequency shows frequencies on the audiogram (up to 20 kHz for
the Affinity2.0
). However, you will only be able to test in the frequency
.0
range the selected headset is calibrated for.
High Frequency Zoom
the high frequency range.
Single audiogram toggles between viewing the information of both ears in
a single graph and two separate graphs.
Multi frequencies
activate testing with frequencies in between the
3
standard audiogram points. The frequency resolution can be adjusted in
the AC440 setup.
Synchronize channels locks the two channels together. This function may
be used to perform synchronous masking.
2
activates high frequency testing and zooms in on
Page 29