6. Maintenance schedule
6.1. Reminder of use
The maintenance operations to be carried out are described in the maintenance schedule. The interval for this is supplied as a guide
and for generating sets operating with fuel and oil which conform to the specifications given in this manual.
If the generating set is used under extreme conditions, the interval between the maintenance operations must be shortened.
6.2. Maintenance table
Operations to be
carried out when
Component
the expiry date is
reached
Screws and
Check
bolts
Check the level
Engine oil
Change
Oil cooler
Clean
Oil filter
Replace
Fuel filter
Replace
Check
Air filter
Clean**
Replace***
Starter battery
Check
Check - Clean
Spark plugs
Replace
Generating set
Clean
Valves*
Have checked*
Solenoid
Have checked*
starter*
Fuel line*
Have checked*
** Foam element. *** Paper element.
* Operation(s) to be entrusted to one of our dealers.
If used in dusty conditions, clean the air filter more frequently.
7. Maintenance procedures
Before carrying out any maintenance operation:
- switch off the generating set.
- disconnect the cap(s) of the spark plug(s) and disconnect the starter battery (if fitted).
Warning
Only use original parts or equivalent parts: risk of damage to the generating set.
7.1. Checking bolts, nuts and screws
To prevent faults or breakdowns, carefully check all the nuts, bolts and screws on a daily basis.
Inspect the entire generating set before and after each use.
Tighten any loose nuts or bolts.
Danger: The cylinder head bolts must be tightened by a specialist. Refer to the agent for your region.
After:
Every
Each
1 month
3 months
time it is
Or
Or
used
the first 25
every 150
hours
•
•
•
•**
•
Every
Every
3 months
6 months
Or
Or
every 200
every 300
hours
hours
hours
•
•
•
•***
•
•
Every
Every
6 months
Year
Or
Or
every 500
every 600
hours
hours
•
•
•*
•*
Every
2 years
•*