Sime SOLO-DUETTO 25 TSE Instrucciones Para El Instalador Y Para El Servicio De Asistencia página 90

Tabla de contenido

Publicidad

3.5
ACCESS TO
INSTALLER'S
PARAMETERS
For access to the installer's parameters,
press simultaneously the keys
or 2 seconds (3 fig. 13).
For example, the parameter PAR 23 is
visualised on the display of the control
panel in the following way:
The paramet er s scr oll for war ds and
backwards with the key
the default parameters can be changed
with the keys
and
.
The standard visualisation returns automa-
tically after 60 seconds, or by pressing one
of the control keys (2 fig. 13) excluded the
key RESET.
3.5. 1
Replacing the board or
RESETTING parameters
If the electronic board is replaced or reset,
it is necessary to configure PAR 2 by asso-
ciating the following values to each type of
boiler to be able to restart the boiler:
BOILER
Double pump and
D.H.W. pressure
(HIGH INERTIA)
D.H.W. tank with diverter
valve and D.H.W. sensor
(HIGH INERTIA)
D.H.W. tank with double pump
and D.H.W. sensor
(HIGH INERTIA)
D.H.W. tank with
diverter valve and
D.H.W. thermostat
or heating only
(HIGH INERTIA)
D.H.W. tank with double pump
and D.H.W. thermostat
(HIGH INERTIA)
Heating only
and antifreese sensor
(HIGH INERTIA)
NOTE: the inside of the upper door of the
boiler panel has a label with the values
that have to be set for PAR 2 (fig. 16).
90
FAST CONFIGURATION
PAR DESCRIPTION
1
and
2
Hydraulic configuration
3
Timetable 2 programmer
4
Pressure transducer disabler
5
Assignment of auxiliary relay AUX
and
and
6
Luminous bar indicating presence
of voltage
7
Allocation of CR73 channels
8
9
10 Remote control option setting
11
Correction values external sensor
12 Backlighting duration
PAR 2
13
1
14
Setting second input TA
15
2
16
ModBus address
17
ModBus communication configuration
3
19
Type circuit
D.H.W. - HEATING
PAR DESCRIPTION
4
20
Minimum heating temperature Zone 1
21
Maximum heating temperature Zone 1
22
Heating curve slope Zone 1
23
Minimum heating temperature Zone 2
24
Maximum heating temperature Zone 2
5
25
Heating curve slope Zone 2
26
Minimum heating temperature Zone 3
27
Maximum heating temperature Zone 3
28
Heating curve slope Zone 3
29
6
30
Post-circulation heating time
31
Maximum heating capacity
32
Zone 1 pump activation delay
33
Start-up delay
34
Additional source activation threshold
35
Boiler antifreeze
36
37
Band saturation
flowmeter modulation
38
D.H.W. post-circulation time
39
Anti-legionella
(only D.H.W tank))
PARAMETERS INSTALLER
RANGE
MEASUREMENT
-- = ND
1 ... 6
1 = DHW + Recirc. pump
2 = DHW
3 = Recirculation pump
0 = Disabled
1 = Enabled 0-4 BAR
2 = Enabled 0-6 BAR
3 = Enabled 0-4 BAR (NO ALL 09)
4 = Enabled 0-6 BAR (NO ALL 09)
1 = Remote supply
2 = Recirculation pump
3 = Automatic load.
4 = Remote alarm NC
5 = Heat pump
6 = Zone 2 valve
0 = Disabled
1 = Enabled
0 = Not assigned
1 = Circuit 1
2 = Three-zone circuit
1 = CR 73
2 = CR 53
3 = RVS 43. 1 43
4 = RVS 46.530
5 = RVS 61.843
-5 ... +5
-- = Always
0 = Never
1 ... 199
-- = Contact TA
5... 1 60 = Input 0... 1 0VDC
-- = Not enabled
1...31 = Slaves
1 ... 30
0 = Two zones
1 = Three zones
RANGE
MEASUREMENT
PAR 64 OEM ... PAR 21
PAR 20 ... PAR 65 OEM
3 ... 40
PAR 64 OEM ... PAR 24
PAR 23 ... PAR 65 OEM
3 ... 40
PAR 64 OEM ... PAR 27
PAR 26 ... PAR 65 OEM
3 ... 40
0 ... 199
30 ... 100
0 ... 199
0 ... 10
-- , -10 ... 40
0 ... +20
-- = Disabled
0 ... 100
0 ... 199
0 = Disabled
1 = Enabled
UNIT OF
INC/DEC
DEFAULT
UNIT
SETTING
=
=
"- -"
=
=
1
=
=
1
=
=
1
=
=
1
=
=
1
=
=
1
°C
1
0
sec. x 10
1
3
--
--
--
--
1
--
--
1
25
--
--
0
UNIT OF
INC/DEC
DEFAULT
UNIT
SETTING
°C
1
20
°C
1
80
--
1
20
°C
1
20
°C
1
80
--
1
20
°C
1
20
°C
1
80
--
1
20
Sec.
10
30
%
1
100
10 sec.
1
1
Min.
1
3
°C
1
"- -"
°C
1
3
%
1
100
Sec.
1
0
--
--
0

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Solo-duetto 25 bf tseAqua 25 inox bf tseAqua 25 inox tse

Tabla de contenido