Parameter Setting - Sime SOLO-DUETTO 25 TSE Instrucciones Para El Instalador Y Para El Servicio De Asistencia

Tabla de contenido

Publicidad

5
BASIC SYSTEM
MULTI-ZONE SYSTEM WITH VALVE, ROOM THERMOSTAT AND REMOTE CONTROL CR 73 (Code 8092226)
CR
CR
SE
VZ1
TA2
M
R
SE
VZ
6
BASIC SYSTEM
MULTI-ZONE SYSTEM WITH PUMP, ROOM THERMOSTAT AND REMOTE CONTROL CR 73 (Code 8092226)
TA2
SE
CR
SE
M
R
CR
7
SYSTEM WITH DOUBLE TEMPERATURE OUTPUT
MULTI-ZONE SYSTEM WITH VALVE AND CHRONOTHERMOSTAT
TA1
TA2
SE
M
R
SE
TA1
VZ1
TA
TA1
RL
RL1
P
SI
CT1
CT2
VZ1
DAY
ZONA
GIORNO
ZONE
(70°C)
(70°C)
TA2
VZ2
TA2
RL2
P1
VZ2
NIGHT
ZONA
ZONE
NOTTE
(50°C)
(50°C)

PARAMETER SETTING

To use the remote control (CR)
as room reference for a zone,
set: PAR 7 = 1
Set the opening time of the zone
valve VZ:
PAR 33 = "OPENING TIME"
PARAMETER SETTING
To use the remote control
(CR) as room reference for a
zone, set:
PAR 7 = 1
P2
DURING NIGHT TIME THE BOILER
USES A LOWER OUTPUT TEMPE-
RATURE IF DIFFERENT TIMES HAVE
BEEN SET FOR DAY AND NIGHT
AREAS:
gain access to setting the day zone
1 by pressing the key
and chan-
ge the value with the keys
and
. Gain access to setting
the night zone by pressing the key
twice and changing the value
with the keys
and
.
83