OPERATION AND LOGIC

ON
Once the previously listed points have been checked, press key
15 minutes are available for the ignition phase. After ignition and after reaching the control temperature, the
stove interrupts the ignition phase and switches to PREPARATION.
PREPARATION
During the preparation phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and switch to WORK.
OPERATION
During the work phase, the stove reaches the set power set; see following item.
REGULATION OF SET POWER
The set power has 5 operating levels, When the
Power 1 = minimum level - Power 5 = maximum level.
The change must be con rmed by pressing the key
ADJUSTMENT OF SET H2O TEMPERATURE
Set the boiler temperature from 65 - 80°C (set using keys 4 - 5). Pressing the
modi ed using the
or
The change must be con rmed by pressing the key
PUMP OPERATION
OK
The pump activates water circulation when the t° of the water inside the stove reaches approx. 60°C. As the pump always functions above 60°,
an always open heating area is recommended to make product functioning homogenous, preventing overheating blocks. Normally this area
is de ned "Safety zone".
ROOM TEMPERATURE in the models envisioned)
IT IS possible to activate/deactivate the front ventilation and control the room temperature via the Room probe (integrated in the handheld
device). (See "VENTILATION" chapter in the following pages.)
MODULATION and H-OFF
As the water temperature approaches the set point, the boiler starts to modulate automatically bringing itself to the minimum power. If the
temperature increases beyond the set point, it will automatically switch o indicating H OFF and will automatically go back on when the
temperature drops below the set point.
OFF
Press the
key for three seconds.
Once this operation has been performed, the appliance automatically enters the switch-o phase, blocking the supply of pellets.
OK
The ue gas exhaust motor and the hot air ow motor will remain on until the stove temperature has dropped below the default
parameters.
RE IGNITION
The stove can only be re-ignited automatically or manually when the cooling cycle conditions and the preset timer have been satis ed.
key is pressed, the set power is displayed; it can be changed using the
OK
.
OK
keys.
OK
.
for three seconds to ignite the stove.
OK
key allows the temperature set to be displayed; this can be