For correct operation of the insert, during construction of the chimney it is necessary to respect the measurements indicated in the "MINIMUM
CLEARANCE" chapter, which must be realised with non in ammable material.
From the stove clearance measurements stated in the technical features, at least 34 mm of air must be considered in the rear part of the insert.
(see gure 3)
( gure 3)
To safeguard from any overheating, the INSERTO IDRO 800 is supplied with a probe that analyses the temperature inside the structure and
intervenes by reducing the functioning power.
THIS VENTILATION SYSTEM IS TOTALLY INDEPENDENT FROM THE AIR INLET FOR COMBUSTION!!

ASSEMBLY WITH PEDESTAL OPTIONAL

Position the base in the desired point and using the feet, adjust the height required (the bolts are positioned in the lower part of the four
external sides of the pedestal).
Envision a socket on the rear of the pedestal in a way that the plug is accessible once installation has been performed.
Fix the pedestal to the oor using the strong steel plug with diameter
of 8 mm.
Take the sliding base and x it to the pedestal.
Successively follow the same assembly indications as described and
illustrated in the "Assembly with sliding base" chapter on the previous
page.