4 - Undo the nut (E).
5 - Undo the screws (F) and remove the bushes
(G).
6 - Unscrew and replace the threaded rod (H).
7 - Set the bush (L) at the distance as shown in the
figure.
8 - Reassemble the bushes (G) and tighten the
screws (F).
9 - Fully tighten the nut (E).
Important
Lubricate the threaded rod (H) with Teflon
grease (Tecnolube Seal RHEOLUBE 368F,
OKS 265, etc.).
10 - Replace the control panel (D) and the knob (B)
on completion of the operation.
DECOMMISSIONING THE APPLIANCE
Important
This operation must be carried out by
skilled operatives in compliance with the le-
gal requirements with regard to safety at
work. Never dump non-biodegradable ma-
terials, lubricating oils and non-metallic
IT
GB
DE
FR
ES
English
F
H
G
E
components (rubber, PVC, resins, etc.) in
the environment. Dispose of them in ac-
cordance with the relevant legal require-
ments.
- 26 -
F
L
G
IDM-39616003300.tif